21 / 26 page ![]() AN2299 RC calibration Rev2 21/26 5 RC calibration The purpose of RC oscillator calibration is to bring the working frequency into the band of interest (4.0 < F < 4.2MHz) in order to properly set some absolute definitions of time in the device. The calibration can be obtained either by changing the value of current settling resistor which should be connected between pin CLKIN and Vss or by programming of one or two OTP bits (CRC). The first possibility allows a precise calibration to a certain value while the second one allows only coarse calibration in few steps. In general, it is not so important to have a precise frequency of a certain value as long it stays stable under temperature variation or aging. On the other hand, the value of this frequency directly influences the power constant of the meter. For example, if Rogowski coil is used, the constant C changes twice as much as frequency F (dC/C = 2dF/F) but, if CT or shunt is used, the constant C changes as frequency F (dC/C = dF/F). |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|