Back Button AN4043 Datasheet HTML 23Page - STMicroelectronics AN4043 Datasheet HTML 24Page - STMicroelectronics AN4043 Datasheet HTML 25Page - STMicroelectronics AN4043 Datasheet HTML 26Page - STMicroelectronics AN4043 Datasheet HTML 27Page - STMicroelectronics AN4043 Datasheet HTML 28Page - STMicroelectronics AN4043 Datasheet HTML 29Page - STMicroelectronics AN4043 Datasheet HTML 30Page - STMicroelectronics AN4043 Datasheet HTML 31Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 27 / 60 page
background image
AN4043
Electrical characteristics and functions
Doc ID 022726 Rev 2
27/60
Both solutions allow to detect the total current in all three phases of the inverter. The filter is
based on the RSF and CSF network and its time constant is given by:
Equation 5
In addition to the RC time constant, the turn-off propagation delay of the gate driver, tisd
(specified in the datasheet) and the IGBT turn-off time (in the range of tens of ns), must be
considered in the total delay time (tTotal), which is the time necessary to completely switch
off the IGBT once the short-circuit event is detected. Therefore, the tTotal is calculated as
follows:
Equation 6
and the tSF is recommended to be set in the range of 1~2 µs.
In the case of a 3-shunt resistor circuit, a specific control technique can be implemented by
using the three shunt resistors (RSHUNT_U, RSHUNT_V and RSHUNT_W) able to monitor each
phase current.
An example of a short-circuit event is shown in
Figure 17, where it is possible to note the
very fast protection, thanks to the smart shutdown function, against fault events. The main
steps are:
●
t1: collector current IC starts to rise. SC event is not detected yet due to the RC
network on the CIN pin.
●
t2: voltage on VCIN reaches the VREF. SC event is detected and the smart shutdown
starts to turn off the SLLIMM-nano.
●
t3: the SD in activated.
●
t4: the SLLIMM-nano is definitively turned off in 580 ns (including the td(off) time of
IGBT) from SC detection.
Finally, the total disable time is t4-t2 and the total SC action time is t4-t1.
SF
SF
SF
C
R
t
⋅
=
off
isd
SF
Total
t
t
t
t
+
+
=



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com