| 전자부품 데이터시트 검색엔진 |
|
TDC-GP21 데이터시트(PDF) 25 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
TDC-GP21 데이터시트(HTML) 25 Page - ams AG |
|
25 / 91 page ![]() Ultrasonic-Flow-Converter TDC-GP21 2-16 acam messelectronic gmbh - Friedrich-List-Str.4 - 76297 Stutensee - Germany - www.acam.de only about 10 µs. The average current is 4 mA/s * 10 µs = 0.040 µA. IALU typ. 7 nA per calculation Current into ALU during data proccesing including a calibration calculation. Example: At 1000 measurements per second with 3 stops per start the ALU average current is 7 nA * 3000 = 21 µA. IT typ. 2.5 µAs * measure rate The current for a full temperature measurement is typ.2.5µAs. In heat-meters the temperature is measured typically once every 30 seconds. The average current is about 0.085 µA Iana typ. 0.8 mA Current consumption of the integrated analog part of TDC-GP21 during a Time-of-flight (ToF) measurement. The analog part is active for a duration of 250 µs + ToF. Member of the ams Group |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|