17 / 79 page ![]() DocID026171 Rev 6 17/79 VL6180X Functional description 78 2.4.1 Single-shot range/ALS operation A single-shot range or ALS measurement is performed as follows: • Write 0x01 to the SYSRANGE__START register{0x18}. • When the measurement is completed, bit 2 of RESULT__INTERRUPT_STATUS_GPIO{0x4F} will be set. • Similarly, a single-shot ALS measurement is initiated by writing 0x01 to the SYSALS__START register{0x38}. • When the measurement is completed, bit 5 of RESULT__INTERRUPT_STATUS_GPIO{0x4F} will be set. Note that in both cases the start bit, (bit 0) auto-clears. • The range result is read from RESULT__RANGE_VAL{0x62}. • The ALS result is read from RESULT__ALS_VAL{0x50}. • Interrupt status flags are cleared by writing a ‘1’ to the appropriate bit of SYSTEM__INTERRUPT_CLEAR{0x15}. • Bit 0 of RESULT__RANGE_STATUS{0x4D} and RESULT__ALS_STATUS{0x4E} indicate when either sensor is ready for the next operation. • Error codes are indicated in bits [7:4] of the status registers A detailed description of all the user accessible registers is given in Section 6: Device registers. Note: Single-shot ALS and range operations cannot be performed simultaneously. Only one of these operations should be performed at any one time and once started must be allowed to complete before another measurement is started. This is because any current operation will be aborted if another is started. 2.4.2 Continuous range/ALS operation A continuous range or ALS measurement is performed as follows: • Write 0x03 to the SYSRANGE__START or SYSALS__START registers. In both cases, bit 1 of the register sets the mode to continuous • When a measurement is completed either bit 2 or bit 5 of RESULT__INTERRUPT_STATUS_GPIO{0x4F} will be set. • Results are read from RESULT__RANGE_VAL{0x62} or RESULT__ALS_VAL{0x50}. • Interrupt status flags are cleared by writing a ‘1’ to the appropriate bit of SYSTEM__INTERRUPT_CLEAR{0x15} . • Thereafter, measurements will be scheduled according to the relevant inter- measurement period (see SYSRANGE__INTERMEASUREMENT_PERIOD{0x1B} or SYSALS__INTERMEASUREMENT_PERIOD{0X3E}) . • Continuous mode operation can be stopped by writing 0 to either START register. Continuous operation will be halted immediately and any pending measurement will be aborted. Note: It is not recommended to run range and ALS continuous modes simultaneously (i.e. asynchronously). Instead, mode 7 ‘interleaved mode’ in Table 5. should be used. In ‘interleaved mode’, scheduled range and ALS measurements operate off a single timer with a range measurement proceeding immediately after every ALS measurement. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |