| 전자부품 데이터시트 검색엔진 |
|
VL6180X 데이터시트(PDF) 23 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
VL6180X 데이터시트(HTML) 23 Page - STMicroelectronics |
|
23 / 79 page ![]() DocID026171 Rev 6 23/79 VL6180X Functional description 78 2.8.3 Signal-to-noise ratio (SNR) In high ambient conditions range accuracy can be impaired so the SNR threshold is used as a safety limit to invalidate range measurements where the ambient/signal ratio is considered too high.The default ambient/signal ratio limit is 10 (i.e. an SNR of 0.1) which is then encoded in 4.4 format as follows: SYSRANGE__MAX_AMBIENT_LEVEL_MULT{0x2C} = 10 x 16 = 160 To enable the SNR check, set bit 4 in SYSRANGE__RANGE_CHECK_ENABLES (0x02D). A lower setting results in a more aggressive filter which will result in a lower effective range but greater accuracy. A higher setting results in a less aggressive filter which will result in a greater effective range but lower accuracy. The SNR value can be calculated as follows: Note: The SNR value is the inverse of the ambient/signal ratio limit {0x2C}. Note: The optimum value for SNR threshold should be determined in the final application. 2.9 Manual/autoVHV calibration SPAD(e) sensitivity is temperature dependent so VHV(f) calibration is used to regulate SPAD sensitivity over temperature in order to minimize signal rate variation. VHV calibration is performed either manually by the host processor or automatically by internal firmware. Execution time is typically 200 μs so has no impact on normal operation. A VHV calibration is run once at power-up and then automatically after every N range measurements defined by the SYSRANGE__VHV_REPEAT_RATE{0x31} register. AutoVHV calibration is disabled by setting this register to 0. Default is 255. If autoVHV is disabled it is recommended to run a manual VHV calibration periodically to recalibrate for any significant temperature variation. A manual VHV calibration is performed by setting SYSRANGE__VHV_RECALBRATE{0x2E} to 1. This register auto-clears. This operation should only be performed in software standby. 2.10 History buffer The history buffer is a 8 x 16-bit memory which can be used to store the last 16 range measurements (8-bit) or 8 ALS samples (16-bit). Use of the history buffer is controlled via register SYSTEM__HISTORY_CTRL{0x12}. There are 3 basic functions: • enable • range or ALS selection • clear buffer SNR RESULT__RANGE_RETURN_SIGNAL_COUNT{0x6C} RESULT__RANGE_RETURN_AMB_COUNT{0x74} * 6 -------------------------------------------------------------------------------- - = e. Photon detectors - Single Photon Avalanche Diodes f. VHV is an adjustable SPAD bias voltage and stands for Very High Voltage (typically around 14 V). Also sometimes referred to as CP (Charge Pump). |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |