30 / 51 page ![]() Low side driver L9301 30/51 DocID028688 Rev 6 9.3.4 OFF state diagnostic The device provides the off-state diagnostic for each channel. The short to ground and open load faults can be detected. The fault is reported in a SPI register. Figure 12. LS configuration diagnostic The diagnostic blanking time is configurable through the dedicated diagoff_blank_sel bit. 9.3.5 DLOSS In case the device is configured as low side and external diodes are used for freewheeling, there is the possibility through a dedicated SPI bit to enable the ‘diode loss’ diagnosis that is used to detect if the external diode is no more connected checking if during the OFF phase the internal clamp is activated. Another SPI bit allows to configure the actions to be taken in case of DLOSS fault. Table 20. LS diagnostic DIAGOL DIAGLV FAULT DETECTION 0 0 no fault 0 1 not possible 1 0 open load 1 1 short to ground |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|