Back Button LT8253EUFDM Datasheet HTML 7Page - Analog Devices LT8253EUFDM Datasheet HTML 8Page - Analog Devices LT8253EUFDM Datasheet HTML 9Page - Analog Devices LT8253EUFDM Datasheet HTML 10Page - Analog Devices LT8253EUFDM Datasheet HTML 11Page - Analog Devices LT8253EUFDM Datasheet HTML 12Page - Analog Devices LT8253EUFDM Datasheet HTML 13Page - Analog Devices LT8253EUFDM Datasheet HTML 14Page - Analog Devices LT8253EUFDM Datasheet HTML 15Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 11 / 20 page
background image
LT8253/LT8253A
11
Rev. 0
For more information www.analog.com
OPERATION
Start-Up and Fault Protection
Figure 6 shows the start-up and fault sequence for the
LT8253/LT8253A. During the POR state, the SS pin is
hard pulled down with a 100Ω to ground. In a pre-biased
condition, the SS pin has to be pulled below 0.2V to enter
the INIT state, where the LT8253/LT8253A wait 10µs so
that the SS pin can be fully discharged to ground. After
the 10µs, the LT8253/LT8253A enter the UP/PRE state
when the VOUTEN signal goes high.
During the UP/PRE state, the SS pin is charged up by a
12.5µA pull-up current while the switching is disabled.
Once the SS pin is charged above 0.25V, the LT8253/
LT8253A enter the UP/TRY state. After 10µs in the UP/
TRY state, the LT8253/LT8253A enter the UP/RUN state.
POR
• SS hard pull down
• Switching disabled
• No short detection
INIT
• SS hard pull down
• Switching disabled
• No short detection
POR = HI
SS < 0.2V
UP/TRY
• SS 12.5µA pull up
• Switching disabled
• No short detection
UP/PRE
• SS 12.5µA pull up
• Switching disabled
• No short detection
Wait 10µs and
VOUTEN = HI
SS > 0.25V
UP/RUN
• SS 12.5µA pull up
• Switching enabled
• No short detection
OK/RUN
• SS 12.5µA pull up
• Switching enabled
• Short detection
Wait 10µs
SS > 1.75V
DOWN/STOP
• SS 1.25µA pull down
• Switching disabled
• No short detection
FAULT/RUN
• SS 1.25µA pull down
• Switching enabled
• Short detection
SS < 0.2V and
VOUTEN = HI
SHORT
SS < 1.7V
8253A F06
Figure 6. Start-Up and Fault Sequence
During the UP/RUN state, the switching is enabled and
the start-up of the output voltage VOUT is controlled by
the voltage on the SS pin. When the SS pin voltage is less
than 1V, the LT8253/LT8253A regulate the FB pin voltage
to the SS pin voltage instead of the 1V reference. This
allows the SS pin to program soft-start by connecting an
external capacitor from the SS pin to GND. The internal
12.5µA pull-up current charges up the capacitor, creating
a voltage ramp on the SS pin. As the SS pin voltage rises
linearly from 0.25V to 1V and above, the output voltage
VOUT rises smoothly to its final regulation voltage.
Once the SS pin is charged above 1.75V, the LT8253/
LT8253A enter the OK/RUN state, where the output
short detection is activated. The output short means VFB
< 0.25V. When the output short happens, the LT8253/
LT8253A enter the FAULT/RUN state, where a 1.25µA pull-
down current slowly discharges the SS pin with the other
conditions the same as the OK/RUN state. Once the SS pin
is discharged below 1.7V, the LT8253/LT8253A enter the
DOWN/STOP state, where the switching is disabled and
the short detection is deactivated with the previous fault
latched. Once the SS pin is discharged below 0.2V and
the VOUTEN signal is still high, the LT8253/LT8253A go
back to the UP/RUN state.
In an output short condition, the LT8253/LT8253A can
be set to hiccup, latch-off, or keep-running fault pro-
tection mode with a resistor between the SS and VREF
pins. Without any resistor, the LT8253/LT8253A will
hiccup between 0.2V and 1.75V and go around the UP/
RUN, OK/RUN, FAULT/RUN, and DOWN/STOP states
until the fault condition is cleared. With a 499kΩ resis-
tor, the LT8253/LT8253A will latch off until the EN/UVLO
is toggled. With a 100kΩ resistor, the LT8253/LT8253A
will keep running regardless of the fault.The front page
shows a typical LT8253/LT8253A application circuit. This
Applications Information section serves as a guideline of
selecting external components for typical applications. The
examples and equations in this section assume continuous
conduction mode unless otherwise specified.
Switching Frequency Selection
The LT8253/LT8253A use a constant frequency control
scheme, 150kHz-650kHz for LT8253 and 600kHz-2MHz



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com