140 / 239 page ![]() 8.0 Health Management (HM) (Continued) www.national.com 140 Revision1.1 When the START bit in Configuration register is 0, sensor monitoring is disabled. However, following VSB3 power-up, and after the READY bit becomes 1, Temperature Zone1 is monitored regardless of the state of the START bit. If the temperature data of Temperature Zone1 is above the default value of the Temperature Critical Limit Zone1 register (+110 °C), ETC is asserted turning the Main power supply off. In addition, the CRIT1_ERR bit in Status Register 3 is set to 1. This feature protects the CPU from overheating at VSB3 power-up before the HM is configured by the software for the first time. The LOCK_LIM bit in the Monitoring Control Register (see Section 8.5.54 on page 176) can lock the Limit registers. 8.3 HM SMBUS ACCESS This section describes the SMBus transactions protocol used by the HM (see also Section 8.2.1 on page 127). 8.3.1 Write Transaction This transaction writes a byte of data to an HM register. The specific register is accessed using an 8-bit offset address. 8.3.2 Read Transaction This transaction reads a byte of data from an HM register. The specific register is accessed using an 8-bit offset address. This transaction is executed in two stages: 1. The master executes an SMBus write transaction, which conveys the Offset Address information to the HM. During this stage, the data is read from the specific register into a read buffer. This stage has no Stop condition. 2. Following a Restart condition, the master executes an SMBus read transaction. During this stage the data is transferred from the read buffer to the master. P Slave Address Offset Address Data (S.A, Write) (OA7-OA0) (Command) S A A A = Start condition = ACK by slave S A = Stop condition P P Slave Address Data (S.A, Write) ( Command) S A A N = Start condition = Restart condition S = Stop condition P Slave Address (S.A, Read) R A = ACK by slave A R A = ACK by master N = NACK by master Offset Address Winbond Electronics Corp. Advanced PC Product Center |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |