63 / 82 page ![]() SMCxxxAF CF-ATA command description 63/82 9.13 Recalibrate command (1Xh) This command is effectively a NOP command to the card and is provided for compatibility purposes. Table 61 defines the Recalibrate command byte sequence. 9.14 Request Sense command (03h) This command requests extended error information for the previous command. Table 62 defines the Request Sense command byte sequence. Table 63 defines the valid extended error codes. The extended error code is returned to the host in the Error register. Table 60. Read Verify Sector(s) Bit 7 6 5432 1 0 Command (7) 40h or 41h C/D/H (6) 1 LBA 1 Drive Head (LBA 27-24) Cyl High (5) Cylinder High (LBA 23-16) Cyl Low (4) Cylinder Low (LBA 15-8) Sect Num (3) Sector Number (LBA 7-0) Sect Cnt (2) Sector Count Feature (1) X Table 61. Recalibrate Bit 7 6 5432 1 0 Command (7) 1Xh C/D/H (6) 1 LBA 1 Drive X Cyl High (5) X Cyl Low (4) X Sect Num (3) X Sect Cnt (2) X Feature (1) X |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|