Back Button AS8506 Datasheet HTML 29Page - ams AG AS8506 Datasheet HTML 30Page - ams AG AS8506 Datasheet HTML 31Page - ams AG AS8506 Datasheet HTML 32Page - ams AG AS8506 Datasheet HTML 33Page - ams AG AS8506 Datasheet HTML 34Page - ams AG AS8506 Datasheet HTML 35Page - ams AG AS8506 Datasheet HTML 36Page - ams AG AS8506 Datasheet HTML 37Page - ams AG Next Button
Zoom Inzoom in Zoom Outzoom out
 33 / 89 page
background image
ams Datasheet, Confidential:2013-Sep [1-00]
AS8506 – 33
Detaile d Desc rip t ion
Trigger Event
The AS8506 device enters into NORMAL mode only when a valid
command is present on the TRIG_IN pin. There are two
commands in the device.
• Diagnosis command
• Cell balance command
When a high pulse of width Tdiag_cmd as shown in Figure 27, is
given on TRIG_IN pin, the device performs the following
operations.
• Compares all connected cell voltages with the set lower
operating voltage threshold, and if any of the cell voltage
is less than lower threshold, then sets a corresponding flag
in the cel_low_thsld_stat_reg register. This is indicated by
high pulse on CVT_NOK_OUT pin.
• Compares all connected cell voltages with the set higher
operating voltage threshold, and if any of the cell voltage
is more than higher threshold, then sets a corresponding
flag in the cel_high_thsld_stat_reg register. This is
indicated by high pulse on CVT_NOK_OUT pin.
• Sets a corresponding flag in the temp_stat_reg register if
ambient temperature or internal chip temperature is
higher than respective thresholds. This is indicated by
high pulse on CVT_NOK_OUT pin.
• It will enable SAR ADC and starts measuring each cell
voltage, and then measures temperature channel
measurement. The 12 bits digital value will be stored in
corresponding registers.
Thus, on diagnosis command the device gives the cell operating
voltage, ambient temperature and internal temperature status
with respect to its safe operating range.
When the TRIG_IN pin is ‘High’ for longer than the status
command, the device enters into Balance phase. Depending
upon cell voltage status, the device starts balancing the cell
voltages. The cell voltage balancing is continued till the high
voltage on the TRIG_IN pin. As soon as TRIG_IN goes ‘Low’, the
device stops balancing and enters into WAIT mode. Thus, the
microcontroller has full control over the balancing time and
stop balancing whenever required.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com