| 전자부품 데이터시트 검색엔진 |
|
AN3985 데이터시트(PDF) 83 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
AN3985 데이터시트(HTML) 83 Page - STMicroelectronics |
|
83 / 105 page ![]() AN3985 M24LRxx layer Doc ID 022255 Rev 2 83/105 M24LRxx_SetRst_EH_en function This function sends, through the CR95HF, a SetRst_EH_en command to a contactless tag in the field. On receiving the set reset Energy Harvesting Enable command, the M24LRxxE-R contactless tag set or reset the EHenable bit, within the volatile control register. M24LRxx_Check_EH_En function This function sends, through the CR95HF, a Check_EH_En command to a contactless tag in the field. On receiving the Check Energy Harvesting enabled command, the M24LRxxE-R contactless tag reads the control register and sends back its value. Table 141. M24LRxx_SetRst_EH_en function description Prototype u8 M24LRxx_SetRst_EH_en (ISO15693_Tag* MyTag, const u8 Request_flags,const u8* Tag_UID, u8 Set_Reset); Input parameter Request_flags: Specifies the actions to be performed by the contactless tag and whether corresponding fields are present or not. (1) Tag_UID: pointer on the UID (optional) Set_Reset: Enable or disable the energy harvesting. (2) 1. The Address flag indicates if Tag_UID field will be added to the command (addressed mode). 2. Value to enable the energy harvesting: M24LRxx_CONTROL_BYTE_EH_ENABLE Value to disable the energy harvesting: M24LRxx_CONTROL_BYTE_EH_DISABLE Output parameter MyTag: pointer on the structure that contains the tag response Return parameter M24LRxx_ERROR_CODE: The command failed. M24LRxx_ERROR_PARAMETERS_REQUEST_FLAGS: The inventory flag is set. M24LRxx_SUCCESS_CODE: The tag answered the command. Table 142. M24LRxx_Check_EH_En function description Prototype u8 M24LRxx_Check_EH_En (ISO15693_Tag* MyTag, const u8 Request_flags,const u8* Tag_UID); Input parameter Request_flags: Specifies the actions to be performed by the contactless tag and whether corresponding fields are present or not. (1) Tag_UID: pointer on the UID (optional) 1. The Address flag indicates if Tag_UID field will be added to the command (addressed mode). Output parameter MyTag: pointer on the structure that contains the tag response Return parameter M24LRxx_ERROR_CODE: The command failed. M24LRxx_ERROR_PARAMETERS_REQUEST_FLAGS: The inventory flag is set. M24LRxx_SUCCESS_CODE: The tag answered the command. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |