261 / 275 page ![]() DocID022352 Rev 3 261/275 RM0312 ProxSense™ (PXS) 273 22.9.4 ProxSense Interrupt and Status Register (PXS_ISR) Address offset: 0x04 Reset value: 0x00 7654321 0 EOCF FCCF NOISEDETF CIPF SYNCPF SYNC_OVRF Reserved rc rc rc r r r Bit 7 EOCF: End of conversion flag 0: No end of conversion has occurred 1: End of conversion has occurred This status bit is set by hardware when each of the enabled Rx channels has finished converting and the results are ready. EOCF is cleared by hardware when a conversion is launched (when CIPF becomes ‘1’) or when PXSEN = 0. If EOCITEN = 1, the ProxSense interrupt occurs when EOCF transitions to 1. EOCF must be cleared by software before exiting the interrupt service routine. Note: When clearing this flag, it is recommended to write 0x60 to this register to avoid accidentally erasing the other flag bits. The BRES instruction is discouraged since an event may occur between the read and write. Bit 6 FCCF: First conversion completion flag 0: No first conversion completion interrupt has occurred 1: First conversion completion interrupt has occurred This status bit is set by hardware the first time a channel conversion is completed after a conversion has started. Subsequent conversion completions on other channels do not cause this bit to be set. FCCF is cleared by hardware when a conversion is launched (when CIPF becomes ‘1’) or when PXSEN = 0. If FCCITEN = 1, the ProxSense interrupt occurs when FCCF rises. FCCF must be cleared by software before exiting the interrupt service routine. Note: When clearing this flag, it is recommended to write 0xA0 to this register to avoid accidentally erasing the other flag bits. The BRES instruction is discouraged since an event may occur between the read and write. Bit 5 NOISEDETF: Noise detection flag 0: No noise detected 1: Noise detected This status bit is set by hardware if RF noise is detected during a conversion. NOISEDETF is cleared by software. Note: When clearing this flag, it is recommended to write 0xC0 to this register to avoid accidentally erasing the other flag bits. The BRES instruction is discouraged since an event may occur between the read and write. Bit 4 CIPF: Conversion in progress flag 0: No conversion is in progress 1: A conversion is in progress This status bit is set by hardware when the START bit is set and it is cleared by hardware when the conversion is completed. CIPF is read-only. Note: Many control registers are locked (read-only) when CIPF = 1. Note: If PXSEN is set to 0 (by software) during a conversion, the conversion is stopped. In this case, CIPF remains at ‘1’ for as long as 8 µs after which it transitions to ‘0’. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |