433 / 467 page ![]() DocID14587 Rev 14 433/467 RM0016 Analog/digital converter (ADC) 454 Note: When using scan mode, it is not possible to use channels AIN0 to AINn in output mode because the output stage of each channel is disabled when it is selected by the ADC multiplexer. A single conversion is performed for each channel starting with AIN0 and the data is stored in the data buffer registers ADC_DBxR. When the last channel (channel ‘n’) has been converted, the EOC (End of Conversion) flag is set and an interrupt is generated if the EOCIE bit is set. The converted values for each channel can be read from the data buffer registers. The OVR flag is set if one of the data buffer registers is overwritten before it has been read (see Section 24.5.5). Do not clear the SCAN bit while the conversion sequence is in progress. Single scan mode can be stopped immediately by clearing the ADON bit. To start a new SCAN conversion, clear the EOC bit and set the ADON bit in the ADC_CR1 register. Continuous scan mode This mode is like single scan mode except that each time the last channel has been converted, a new scan conversion from channel 0 to channel n starts automatically. The OVR flag is set if one of the data buffer registers is overwritten before it has been read (see Section 24.5.5). Continuous scan mode is started by setting the ADON bit while the SCAN and CONT bits are set. Do not clear the SCAN bit while scan conversion is in progress. Continuous scan mode can be stopped immediately by clearing the ADON bit. Alternatively if the CONT bit is cleared while conversion is ongoing, conversion stops the next time the last channel has been converted. Caution: In scan mode, do not use a bit manipulation instruction (BRES) to clear the EOC flag. This is because this performs a read-modify-write on the whole ADC_CSR register, reading the current channel number from the CH[3:0] register and writing it back, which changes the last channel number for the scan sequence. The correct way to clear the EOC flag in continuous scan mode is to load a byte in the ADC_CSR register from a RAM variable, clearing the EOC flag and reloading the last channel number for the scan sequence 24.5.5 Overrun flag The OVR error flag is set by hardware in buffered continuous mode, single scan or continuous scan modes. It indicates that one of the ten data buffer registers was overwritten by a new converted value before the previous value was read. In this case, it is recommended to start a new conversion. Note: Setting the ADON bit automatically clears the OVR flag. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |