56 / 95 page ![]() Data Sheet AD4080 DIGITAL FEATURES analog.com Rev. 0 | 56 of 95 FIFO Mode Selection and Configuration There are four distinct modes in which the data FIFO of the AD4080 can be configured. The active mode is selected by setting the FIFO_MODE bits in the general configuration register (see the General Configuration Register section, Address 0x1C). By default, the FIFO is disabled (FIFO_MODE = 00). The modes are designed to fit the use case requirements of different applications., Table 27 provides details about each FIFO mode and their applicable use cases. Table 27. FIFO Configuration Modes (FIFO_MODE) FIFO_MODE Bit Value FIFO Mode Description Use Case 00 FIFO disabled FIFO is not used. This value also resets and rearms the event trigger. Continuous convert mode, and FIFO is not in use. 01 Immediate trigger mode In this mode, the data capture is initiated immediately after receipt of the first valid converter result and continues until [N = WATERMARK] results are loaded into the FIFO memory. User is interested in burst acquisition(s) of [N = WATERMARK] results, initiated by setting this FIFO_MODE, Bits[1:0] value. Upon read back from the FIFO, FIFO_READ_DONE indicates when [N = WATERMARK] results are read from the FIFO. 10 Event trigger capture, read latest WATERMARK The data capture into the FIFO memory is initiated by the user-selected event method. The result counter initiates by the event, and data captures to the FIFO stop once [N = WATERMARK] results are captured. User is interested in burst acquisition(s) of [N = WATERMARK] results, initiated by an event. Only result data after the event is of interest. Upon read back from the FIFO, FIFO_READ_DONE indicates when [N = WATERMARK] results have been read from the FIFO. 11 Event trigger capture mode, read all FIFO The data capture immediately initiates after the receipt of the first valid converter result. User is interested in burst acquisition(s) of [N = WATERMARK] results initiated by an event. The full FIFO contents are read in this mode. In this mode, the user can read [N = WATERMARK] results after the event and (16,384 − [N = WATERMARK]) before the event. Only WATERMARK values that are multiples of four are valid in this mode. The FIFO continuously fills until an event is detected. If no event is detected before the FIFO fills (that is, 16,384 results are written to memory), the memory continues to fill with the oldest results discarded on a first in, first out basis. Upon receipt of the selected event method, a result counter counts up to [N = WATERMARK]. Data capture stops once the WATERMARK is reached. In this mode, once the FIFO is filled, the position in the FIFO memory at which the event occurred gets automatically stored in the FIFO_WATERMARK register. The value read back from FIFO_WATERMARK allows the user to distinguish which of the stored results captured before the event from those that were captured after the event. Further details can be seen in the example given in the Event Trigger Capture Mode, Read All FIFO section. Upon read back from the FIFO, FIFO_READ_DONE indicates when 16,384 results are read from the FIFO. The full memory read back contains [N = WATERMARK] results after the event. If N in this case is less than 16,384, the remaining contents of the FIFO contain the conversion results prior to the event. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |