25 / 52 page ![]() 25 3638F–DFLASH–4/08 AT45DB021D 13. “Power of 2” Binary Page Size Option “Power of 2” binary page size Configuration Register is a user-programmable nonvolatile regis- ter that allows the page size of the main memory to be configured for binary page size (256 bytes) or the DataFlash standard page size (264 bytes). The “power of 2” page size is a One-time Programmable (OTP) register and once the device is configured for “power of 2” page size, it cannot be reconfigured again. The devices are initially shipped with the page size set to 264 bytes. The user has the option of ordering binary page size (256 bytes) devices from the factory. For details, please refer to Section 26. ”Ordering Information” on page 47. For the binary “power of 2” page size to become effective, the following steps must be followed: 1. Program the one-time programmable configuration resister using opcode sequence 3DH, 2AH, 80H and A6H (please see Section 13.1). 2. Power cycle the device (i.e. power down and power up again). 3. The page for the binary page size can now be programmed. If the above steps are not followed to set the page size prior to page programming, incorrect data during a read operation may be encountered. 13.1 Programming the Configuration Register To program the Configuration Register for “power of 2” binary page size, the CS pin must first be asserted as it would be with any other command. Once the CS pin has been asserted, the appropriate 4-byte opcode sequence must be clocked into the device in the correct order. The 4-byte opcode sequence must start with 3DH and be followed by 2AH, 80H, and A6H. After the last bit of the opcode sequence has been clocked in, the CS pin must be deasserted to initiate the internally self-timed program cycle. The programming of the Configuration Register should take place in a time of t P, during which time the Status Register will indicate that the device is busy. The device must be power-cycled after the completion of the program cycle to set the “power of 2” page size. If the device is powered-down before the completion of the program cycle, then setting the Configuration Register cannot be guaranteed. However, the user should check bit 0 of the status register to see whether the page size was configured for binary page size. If not, the command can be re-issued again. Figure 13-1. Erase Sector Protection Register 14. Manufacturer and Device ID Read Identification information can be read from the device to enable systems to electronically query and identify the device while it is in system. The identification method and the command opcode comply with the JEDEC standard for “Manufacturer and Device ID Read Methodology for SPI Compatible Serial Interface Memory Devices”. The type of information that can be read from the device includes the JEDEC defined Manufacturer ID, the vendor specific Device ID, and the ven- dor specific Extended Device Information. Command Byte 1 Byte 2 Byte 3 Byte 4 Power of Two Page Size 3DH 2AH 80H A6H Opcode Byte 1 Opcode Byte 2 Opcode Byte 3 Opcode Byte 4 CS Each transition represents 8 bits SI |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |