| 전자부품 데이터시트 검색엔진 |
|
MMA685X 데이터시트(PDF) 36 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
MMA685X 데이터시트(HTML) 36 Page - Freescale Semiconductor, Inc |
|
36 / 52 page ![]() Sensors 36 Freescale Semiconductor, Inc. MMA685x 3.8.9 Arming Function MMA685x provides the option for an arming function with 3 modes of operation. The operation of the arming function is se- lected by the state of the A_CFG bits in the DEVCFG register. Reference Section 4.5 for the operation of the Arming function with exception conditions. Error conditions do not impact prior arming function responses. If an error occurs after an arming activation, the corresponding pulse stretch for the existing arming condition will continue. However, new acceleration reads will not update the arming function regardless of the acceleration value. 3.8.9.1 Arming Function: Moving Average Mode In moving average mode, the arming function runs a moving average on the offset cancelled output. The number of samples used for the moving average (k) is programmable via the AWS_x[1:0] bits in the ARMCFGX register. Reference Section 3.1.8 for register details. ARM_MAn = (OCn + OCn-1 + ... + OCn+1-k)/k Where n is the current sample. The sample rate is determined by the SPI acceleration data sample rate. At the falling edge of CS for an acceleration data SPI response, the moving average is updated with a new sample. Reference Figure 26. The SPI acceleration data sample rate must meet the minimum time between requests (tACC_REQ_x) specified in Section 2.5. The moving average output is compared against positive and negative 8-bit thresholds that are programmed via the ARMT_x registers. Reference Section 3.1.9 for register details. If the moving average equals or exceeds either threshold, an arming con- dition is indicated, the ARM output is asserted, and the pulse stretch counter is set as described in Section 3.8.9.4. The ARM output is de-asserted only when the pulse stretch counter expires. Figure 26 shows the arming output operation for different SPI conditions. Figure 24. Arming Function Block Diagram - Moving Average Mode Offset Cancellation AWS_P[1:0] APS[3:0] Pulse Stretch ARM Gating I/O ARMT_N[7:0] ARMT_P[7:0] Moving Average Positive Moving Average Negative AWS_N[1:0] OffCanc_ARM[10:0] |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |