457 / 923 page ![]() 419 (6) Operation when Error Occurs during Normal Mode Operation, and Operation is Restarted in Reset-Synchronous PWM Mode: Figure 12.101 shows an explanatory diagram of the case where an error occurs in normal mode and operation is restarted in reset-synchronous PWM mode after re-setting. 1 RESET 2 TMDR (normal) 3 TOER (1) 5 PFC (MTU) 4 TIOR (1 init 0 out) 6 TSTR (1) 7 Match 8 Error occurs 9 PFC (PORT) 10 TSTR (0) 11 TIOR (0 init 0 out) 12 TIOR (disabled) 13 TOER (0) 14 TOCR 15 TMDR (CPWM) 16 TOER (1) 17 PFC (MTU) 18 TSTR (1) MTU output TIOC3A TIOC3B TIOC3D Port output PE9 PE8 PE11 High-Z High-Z High-Z Figure 12.101 Error Occurrence in Normal Mode, Recovery in Reset-Synchronous PWM Mode 1 to 13 are the same as in figure 12.100. 14.Select the reset-synchronous PWM output level and cyclic output enabling/disabling with TOCR. 15.Set reset-synchronous PWM. 16.Enable channel 3 and 4 output with TOER. 17.Set MTU output with the PFC. 18.Operation is restarted by TSTR. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|