479 / 923 page ![]() 441 (27) Operation when Error Occurs during Reset-Synchronous PWM Mode Operation, and Operation is Restarted in Complementary PWM Mode: Figure 12.123 shows an explanatory diagram of the case where an error occurs in reset-synchronous PWM mode and operation is restarted in complementary PWM mode after re-setting. 1 RESET 2 TOCR 3 TMDR (RPWM) 5 PFC (MTU) 4 TOER (1) 6 TSTR (1) 7 Match 8 Error occurs 9 PFC (PORT) 10 TSTR (0) 11 TOER (0) 12 TOCR 13 TMDR (CPWM) 14 TOER (1) 15 PFC (MTU) 16 TSTR (1) MTU output TIOC3A TIOC3B TIOC3D Port output PE9 PE8 PE11 High-Z High-Z High-Z Figure 12.123 Error Occurrence in Reset-Synchronous PWM Mode, Recovery in Complementary PWM Mode 1 to 10 are the same as in figure 12.121. 11.Disable channel 3 and 4 output with TOER. 12.Select the complementary PWM output level and cyclic output enabling/disabling with TOCR. 13. Set complementary PWM. (The MTU cyclic output pin goes low.) 14.Enable channel 3 and 4 output with TOER. 15.Set MTU output with the PFC. 16.Operation is restarted by TSTR. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|