| 전자부품 데이터시트 검색엔진 |
|
M58PR512LE 데이터시트(PDF) 32 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
M58PR512LE 데이터시트(HTML) 32 Page - STMicroelectronics |
|
32 / 119 page ![]() Command interface M58PR256LE, M58PR512LE, M58PR001LE 32/119 4.16 Block Lock-down command The Block Lock-down command locks down a locked or unlocked block. A locked-down block cannot be programmed or erased. The lock status of a locked-down block cannot be changed when WP is low, VIL. When WP is high, VIH, the lock-down function is disabled and the locked blocks can be individually unlocked by the Block Unlock command. Two bus write cycles are required to issue the Block Lock-down command. ● The first bus cycle sets up the Block Lock-down command. ● The second bus write cycle latches the block address and locks-down the block. The lock status can be monitored for each block using the Read Electronic Signature command. Locked-down blocks revert to the locked (and not locked-down) state when the device is reset on power-down. Table 22 shows the Lock Status after issuing a Block Lock-down command. Refer to Section 12: Block locking for a detailed explanation and Appendix C, Figure 25: Main array and EFA locking operations flowchart and pseudocode for a flowchart for using the Lock-down command. 4.17 Blank Check command The Blank Check command checks whether a main array block has been completely erased. Only one block at a time can be checked. Two bus cycles are required to issue the Blank Check command: ● The first bus cycle writes the Blank Check command to any address in the block to be checked. ● The second bus cycle writes the Blank Check Confirm command (D0h) to any address in the block to be checked and starts the blank check operation. If the second bus cycle is not Blank Check Confirm, Status Register bits SR4 and SR5 are set to ‘1’ and the command aborts. Once the command is issued the addressed bank automatically enters the Status Register mode and further reads within the bank output the Status Register contents. The only operation permitted during blank check is Read Status Register. Dual operations are not supported while a blank check operation is in progress. Blank check operations cannot be suspended and are not allowed while the device is in program/erase suspend. The SR7 Status Register bit indicates the status of the blank check operation in progress: SR7 = ‘0’ means that the blank check operation is still ongoing. SR7 = ‘1’ means that the operation is complete. The SR5 Status Register bit goes High (SR5 = ‘1’) to indicate that a blank check operation has failed. At the end of the operation the bank remains in the Read Status Register mode until another command is written to the command interface. See Appendix C, Figure 26: Blank check flowchart and pseudocode for a suggested flowchart for using the Blank Check command. Typical Blank Check times are provided in Figure 23: Program/erase times and endurance cycles. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |