46 / 119 page ![]() Status Register M58PR256LE, M58PR512LE, M58PR001LE 46/119 6 Status Register The Status Register provides information on the current or previous program or erase operations. Issue a Read Status Register command to read the contents of the Status Register (refer to Section 4.2 for more details on the command itself). To output the contents, the Status Register is latched and updated on the falling edge of the Chip Enable or Output Enable signals, and can be read until Chip Enable or Output Enable returns to VIH. The Status Register can only be read using single asynchronous or single synchronous reads. Bus read operations from any address within the bank always read the Status Register during program and erase operations if no Read Array command has been issued. The various bits convey information about the status and any errors of the operation. Bits SR7, SR6, SR2 and SR0 give information on the status of the device and are set and reset by the device. Bits SR9, SR8, SR5, SR4, SR3 and SR1 give information on errors. They are set by the device but must be reset by issuing a Clear Status Register command or a hardware reset. If an error bit is set to ‘1’ the Status Register should be reset before issuing another command. The bits in the Status Register are summarized in Table 14: Status Register bits. Refer to Table 14 in conjunction with the following text descriptions. 6.1 Control program mode status bit (SR9) The control program mode status bit, SR9, indicates whether an error occurred while writing to a program region that is configured in control program mode. The SR9 bit should be read once the Program/Erase Controller status bit SR7 is set to ‘1’ (Program/Erase Controller inactive). SR9 is set to 1 when the user attempts to program object data in a control mode region. When: ● SR9 = 0, the program operation completed successfully. ● SR9 = 1, the program operation failed. Once set to ‘1’, SR9 can only be cleared by issuing a Clear Status Register command or through a hardware reset. SR9 should be cleared before a new program command is issued, otherwise the new command appears to fail. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |