81 / 252 page ![]() Page 67 TMP86CS49FG Note 1: After clearing WDTOUT to “0”, the program cannot set it to “1”. Note 2: fc: High-frequency clock [Hz], fs: Low-frequency clock [Hz], *: Don’t care Note 3: WDTCR1 is a write-only register and must not be used with any of read-modify-write instructions. If WDTCR1 is read, a don’t care is read. Note 4: To activate the STOP mode, disable the watchdog timer or clear the counter immediately before entering the STOP mode. After clearing the counter, clear the counter again immediately after the STOP mode is inactivated. Note 5: To clear WDTEN, set the register in accordance with the procedures shown in “6.2.3 Watchdog Timer Disable”. Note 1: The disable code is valid only when WDTCR1<WDTEN> = 0. Note 2: *: Don’t care Note 3: The binary counter of the watchdog timer must not be cleared by the interrupt task. Note 4: Write the clear code 4EH using a cycle shorter than 3/4 of the time set in WDTCR1<WDTT>. 6.2.2 Watchdog Timer Enable Setting WDTCR1<WDTEN> to “1” enables the watchdog timer. Since WDTCR1<WDTEN> is initialized to “1” during reset, the watchdog timer is enabled automatically after the reset release. Watchdog Timer Control Register 1 WDTCR1 (0034H) 76 54 321 0 (ATAS) (ATOUT) WDTEN WDTT WDTOUT (Initial value: **11 1001) WDTEN Watchdog timer enable/disable 0: Disable (Writing the disable code to WDTCR2 is required.) 1: Enable Write only WDTT Watchdog timer detection time [s] NORMAL1/2 mode SLOW1/2 mode Write only DV7CK = 0 DV7CK = 1 00 225/fc 217/fs 217/fs 01 223/fc 215/fs 215fs 10 221fc 213/fs 213fs 11 219/fc 211/fs 211/fs WDTOUT Watchdog timer output select 0: Interrupt request 1: Reset request Write only Watchdog Timer Control Register 2 WDTCR2 (0035H) 76 543 21 0 (Initial value: **** ****) WDTCR2 Write Watchdog timer control code 4EH: Clear the watchdog timer binary counter (Clear code) B1H: Disable the watchdog timer (Disable code) D2H: Enable assigning address trap area Others: Invalid Write only |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |