| 전자부품 데이터시트 검색엔진 |
|
STAMP0 데이터시트(PDF) 26 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
STAMP0 데이터시트(HTML) 26 Page - STMicroelectronics |
|
26 / 62 page ![]() Architecture STAMP0 26/62 DocID028639 Rev 1 4.6.2 Data transition or change Data changes on the SDA line must only occur when the SCL clock is low. SDA transition while the clock is high is used to identify a START or STOP condition. 4.6.3 Start condition START is identified by a high to low transition of the data bus SDA signal while the clock signal SCL is stable in the high state. A START condition must precede any command for data transfer. 4.6.4 Stop condition STOP is identified by a low to high transition of the data bus SDA signal while the clock signal SCL is stable in the high state. A STOP condition terminates communication between the slave and the bus master. 4.6.5 Data input During the data input the slave samples the SDA signal on the rising edge of clock SCL. For correct device operation the SDA signal must be stable during the rising edge of the clock and the data can change only when the SCL line is low. 4.6.6 Device addressing To start communication between the master and the slave, the master must initiate with a start condition. Following this, the master sends 8 bits onto the SDA line (MSB first) corresponding to the device select address and read or write mode. The 7 most significant bits are the device address identifiers, corresponding to the I²C bus definition. The 8 th bit (LSB) identifies read or write operation RW, this bit is set to 1 in read mode and 0 for write mode. In the STAMP0 device, employing the SA pin, two possible device addresses can be selected: 38 and 78. The former is selected by setting the SA pin equal to zero; the latter is selected by setting the SA input pin equal to one. After a START condition the slave identifies on the bus the device address and if a match is found, it acknowledges the identification on the SDA bus during the 9 th bit time. The byte following the device identification byte is the internal space address. 4.6.7 Write operation Following the START condition the master sends a device select code with the RW bit set to 0. The slave acknowledges this and then waits for the byte of the internal address. After receiving the internal byte address, the slave again responds with an acknowledgement. 4.6.8 Byte write In the byte write mode the master sends one data byte, this is acknowledged by the slave. The master then terminates the transfer by generating a STOP condition. 4.6.9 Multi-byte write The multi-byte write modes can start from any internal address. The master generating a STOP condition terminates the transfer. Obsolete Product(s) - Obsolete Product(s) |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |