45 / 128 page ![]() L99PM72PXP Protection and diagnosis Doc ID 023553 Rev 3 45/128 3.3 High side driver outputs The component provides a total of 4 high side outputs Out1...4, (7 typ. at 25°C) to drive e.g. LED's or hall sensors and 1 high side output OUT_HS with 1 typ. at 25°C). ● The high side outputs switch off in case of: ● VS overvoltage and undervoltage ● Overcurrent ● Overtemperature (TSD1) with pre warning(c) In case of overcurrent or overtemperature (TSD1) condition, the drivers switch off. The according status bit is latched and can be read and optionally cleared by SPI. The drivers remain off until the status is cleared. In case overvoltage or undervoltage condition, the drivers are switched off. The according status bit is latched and can be read and optionally cleared by SPI. If the VLOCK_OUT_EN bit (Control Register 4) is set to ‘1’ the drivers remain off until the status is cleared. If the VLOCK_OUT_EN bit is set to ‘0’ the drivers switch on automatically if the error condition disappears. In case of open load condition, the according status register is latched. The status can be read and optionally cleared by SPI. The High sides are not switched off. For OUT_HS the auto recovery feature (OUTHS_rec_en bit Control Register 4) can be enabled. If this bit is set to ‘1’ the driver automatically restarts from a overload condition. This overload recovery feature is intended for loads which have an initial current higher than the over current limit of the output (e.g. Inrush current of cold light bulbs). During auto recovery mode the over current status bit can not be read from SPI. The device itself cannot distinguish between a real overload and a non linear load like a light bulb. A real overload condition can only be qualified by time. As an example, the micro controller can switch on light bulbs by setting the over current recovery bit for the first 50 ms. After clearing the recovery bit, the output is automatically disabled if the overload condition still exists. In case of a fail safe condition, the high side drivers are switched off. The control bits are set to default values. (except OUT3/FSO if it is used as a High Side Driver Output) Note: The maximum voltage and current applied to the High Side Outputs is specified in 2.1 ‘Absolute Maximum Ratings’. Appropriate external protection may be required in order to respect these limits under application conditions. Each high side driver can be driven whether with a PWM signal or with a internal Timer (see Table 8). For more details please refer to Section 6.2.3: Control Register 1 c. Except OUT3 when configured as FSO Table 8. PWM configuration for high-side outputs High side output PWM channel Internal timer OUT1 PWM 1 Timer 1 OUT2 PWM 2 Timer 2 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |