Back Button H838532H Datasheet HTML 331Page - Renesas Technology Corp H838532H Datasheet HTML 332Page - Renesas Technology Corp H838532H Datasheet HTML 333Page - Renesas Technology Corp H838532H Datasheet HTML 334Page - Renesas Technology Corp H838532H Datasheet HTML 335Page - Renesas Technology Corp H838532H Datasheet HTML 336Page - Renesas Technology Corp H838532H Datasheet HTML 337Page - Renesas Technology Corp H838532H Datasheet HTML 338Page - Renesas Technology Corp H838532H Datasheet HTML 339Page - Renesas Technology Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 335 / 508 page
background image
Section 10 Serial Communication Interface
Rev. 1.00 May 30, 2008 Page 315 of 484
REJ09B0436-0100
(3) Interrupts and Continuous Transmission/Reception
SCI3 can carry out continuous reception using RXI and continuous transmission using TXI. These
interrupts are shown in table 10.10.
Table 10.10 Transmit/Receive Interrupts
Interrupt
Flags
Interrupt Request Conditions
Notes
RXI
RDRF
RIE
When serial reception is performed
normally and receive data is transferred
from RSR to RDR, bit RDRF is set to 1,
and if bit RIE is set to 1 at this time, RXI
is enabled and an interrupt is requested.
(See figure 10.2(a).)
The RXI interrupt routine reads the
receive data transferred to RDR
and clears bit RDRF to 0.
Continuous reception can be
performed by repeating the above
operations until reception of the
next RSR data is completed.
TXI
TDRE
TIE
When TSR is found to be empty (on
completion of the previous transmission)
and the transmit data placed in TDR is
transferred to TSR, bit TDRE is set to 1.
If bit TIE is set to 1 at this time, TXI is
enabled and an interrupt is requested.
(See figure 10.2(b).)
The TXI interrupt routine writes the
next transmit data to TDR and
clears bit TDRE to 0. Continuous
transmission can be performed by
repeating the above operations until
the data transferred to TSR has
been transmitted.
TEI
TEND
TEIE
When the last bit of the character in
TSR is transmitted, if bit TDRE is set to
1, bit TEND is set to 1. If bit TEIE is set
to 1 at this time, TEI is enabled and an
interrupt is requested. (See figure
10.2(c).)
TEI indicates that the next transmit
data has not been written to TDR
when the last bit of the transmit
character in TSR is sent.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com