Back Button HMS91C8032 Datasheet HTML 51Page - Hynix Semiconductor HMS91C8032 Datasheet HTML 52Page - Hynix Semiconductor HMS91C8032 Datasheet HTML 53Page - Hynix Semiconductor HMS91C8032 Datasheet HTML 54Page - Hynix Semiconductor HMS91C8032 Datasheet HTML 55Page - Hynix Semiconductor HMS91C8032 Datasheet HTML 56Page - Hynix Semiconductor HMS91C8032 Datasheet HTML 57Page - Hynix Semiconductor HMS91C8032 Datasheet HTML 58Page - Hynix Semiconductor HMS91C8032 Datasheet HTML 59Page - Hynix Semiconductor Next Button
Zoom Inzoom in Zoom Outzoom out
 55 / 157 page
background image
HMS91C8032/97C8032
52
NOV., 2001 Ver 1.02
at the 10th divide-by-16 rollover after "write to SBUF."
Reception is initiated by a detected 1-to-0 transition at RxD. For
this purpose RxD is sampled at a rate of 16 times whatever baud
rate has been established. When a transition is detected, the di-
vide-by-16 counter is immediately reset, and 1FFH is written into
the input shift register. Resetting the divide-by-16 counter aligns
its rollovers with the boundaries of the incoming bit times.
The 16 states of the counter divide each bit time into 16ths. At the
7th, 8th, and 9th counter states of each bit time, the bit detector
samples the value of RxD. The value accepted is the value that
was seen in at least 2 of the 3 samples. This is done for noise re-
jection. If the value accepted during the first bit time is not 0, the
receive circuits are reset and the unit goes back to looking for an-
other 1-to-0 transition. This is to provide rejection of false start
bits. If the start bit proves valid, it is shifted into the input shift
register, and reception of the reset of the rest of the frame will
proceed.
As data bits come in from the right, 1s shift out to the left. When
the start bit arrives at the leftmost position in the shift register
(which in mode 1 is a 9-bit register), it flags the RX Control block
to do one last shift, load SBUF and RB8, and set RI. The signal
to load SBUF and RB8, and to set RI, will be generated if, and
only if, the following conditions are met at the time the final shift
pulse is generated:
1. R1 = 0, and
2. Either SM2 = 0, or the received stop bit = 1.
If either of these two conditions is not met, the received frame is
irretrievably lost. If both conditions are met, the stop bit goes into
RB8, the 8 data bits go into SBUF, and RI is activated. At this
time, whether the above conditions are met or not, the unit goes
back to looking for a 1-to-0 transition in RxD.
More About Modes 2 and 3
Eleven bits are transmitted (through TxD), or received (through
RxD): a start bit (0), 8 data bits (LSB first), a programmable 9th
data bit, and a stop bit (1). On transmit, the 9th data bit (TB8) can
be assigned the value of 0 or 1. On receive, the th data bit goes
into RB8 in SCON. The baud rate is programmable to either 1/16
or 1/32 the CPU clock frequency in Mode 2. Mode 3 may have a
variable baud rate generated from Timer 1.
Figure 4-18 and Figure 4-19 show a functional diagram of the se-
rial port in Modes 2 and 3. The receive portion is exactly the same
as in Mode 1. The transmit portion differs from Mode 1 only in
the 9th bit of the transmit shift register.
Transmission is initiated by any instruction that uses SBUF as a
destination register. The "write to SBUF" signal also loads TB8
into the 9th bit position of the transmit shift register and flags the
TX Control unit that a transmission is requested. Transmission
commences at S1P1 of the machine cycle following the next roll-
over in the divide-by-16 counter. (Thus, the bit times are synchro-
nized to the divide-by-16 counter, not to the "write to SBUF"
signal.)
The transmission begins with activation of SEND, which puts the
start bit at TxD. One bit time later, DATA is activated, which en-
ables the output bit of the transmit shift register to TxD. The first
shift pulse occurs one bit time after that. The first shift clocks a 1
(the stop bit) into the 9th bit position of the shift register. There-
after, only zeros are clocked in. Thus, as data bits shift out to the
right, zeros are clocked in from the left. When TB8 is at the out-
put position of the shift register, then the stop bit is just to the left
of TB8, and all positions to the left of that contain zeros. This
condition flags the TX Control unit to do one last shift and then
deactivate SEND and set TI. This occurs at the 11th divide-by 16
rollover after "write to SUBF."
Reception is initiated by a detected 1-to-0 transition at RxD. For
this purpose RxD is sampled at a rate of 16 times whatever baud
rate has been established. When a transition is detected, the di-
vide-by-16 counter is immediately reset, and 1FFH is written to
the input shift register.
At the 7th, 8th, and 9th counter states of each bit time, the bit de-
tector samples the value of R-D. The value accepted is the value
that was seen in at least 2 of the 3 samples. If the value accepted
during the first bit time is not 0, the receive circuits are reset and
the unit goes back to looking for another 1-to-0 transition. If the
start bit proves valid, it is shifted into the input shift register, and
reception of the rest of the frame will proceed.
As data bits come in from the right, 1s shift out to the left. When
the start bit arrives at the leftmost position in the shift register
(which in Modes 2 and 3 is a 9-bit register), it flags the RX Con-
trol block to do one last shift, load SBUF and RB8, and set RI.
The signal to load SBUF and RB8, and to set RI, will be generat-
ed if, and only if, the following conditions are met at the time the
final shift pulse is generated:
1. RI = 0, and
2. Either SM2 = 0, or the received 9th data bit = 1
If either of these conditions is not met, the received frame is irre-
trievably lost, and RI is not set. If both conditions are met, the re-
ceived 9th data bit goes into RB8, and the first 8 data bits go into
SBUF. One bit time later, whether the above conditions were met
or not, the unit goes back to looking for a 1-to-0 transition at the
RxD input.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com