전자부품 데이터시트 검색엔진
  Korean  ▼
ALLDATASHEET.CO.KR

X  

UPD17P136ACT 데이터시트(PDF) 137 Page - NEC

부품명 UPD17P136ACT
상세설명  4-BIT SINGLE-CHIP MICROCONTROLLER
PDF  292 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
제조업체  NEC [NEC]
홈페이지  http://www.nec.com/
Logo NEC - NEC

UPD17P136ACT 데이터시트(HTML) 137 Page - NEC

Back Button UPD17P136ACT Datasheet HTML 133Page - NEC UPD17P136ACT Datasheet HTML 134Page - NEC UPD17P136ACT Datasheet HTML 135Page - NEC UPD17P136ACT Datasheet HTML 136Page - NEC UPD17P136ACT Datasheet HTML 137Page - NEC UPD17P136ACT Datasheet HTML 138Page - NEC UPD17P136ACT Datasheet HTML 139Page - NEC UPD17P136ACT Datasheet HTML 140Page - NEC UPD17P136ACT Datasheet HTML 141Page - NEC Next Button
Zoom Inzoom in Zoom Outzoom out
 137 / 292 page
background image
CHAPTER 13 PERIPHERAL HARDWARE
118
13.1.6 Setting of Interval Time
The time interval at which the comparator outputs the coincidence signal is determined by the value set to the
modulo register. The set value N of the modulo register is calculated from interval time T [sec] as follows:
T =
N + 1
= (N + 1)
× TCP
fCP
N = T
× fCP – 1 or N =
T
– 1 (where, N = 1 to 255)
TCP
fCP
: Frequency of count pulse [Hz]
TCP : Cycle of count pulse [sec] (1/fCP = resolution)
• Example of calculating count value from interval time and program
•
Example of setting 7 ms to timer 1 as interval time (system clock: fX = 8 MHz)
Suppose one wanted to set the interval timer to 7 ms. It is impossible to set an interval time of exactly 7 ms
from an 8-MHz system clock. To set an interval time closest to 7 ms, therefore, calculate the count value
by selecting a count pulse (fX/256, resolution: 32
µs) at which the resolution is maximum.
Example of calculation
T = 7 ms, Resolution = 32
µs
N=
T
– 1
(Resolution)
=
7
× 10–3
– 1
32
× 10–6
= 217.75 = 218 (= DAH)
The value of the modulo register at which the interval time is closest to 7 ms is DAH, and the interval time
at that time is 7.008 ms.
Program example
MOV
DBF0,
#0AH
; Stores DAH to DBF by using reserved words “DBF0” and “DBF1”
MOV
DBF1,
#0DH
; Storage
PUT
TMM,
DBF
; Transfers contents of DBF by using reserved word “TMM”
INITFLG TM1EN, TM1RES, TM1CK1, NOT TM1CK0
; Sets TM1EN and TM1RES, sets count pulse of timer 1 to “fX/256”, and starts
; counting, by using embedded macroinstruction “INITFLG”
.
.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com