| 전자부품 데이터시트 검색엔진 |
|
VSC8221 데이터시트(PDF) 39 Page - Microsemi Corporation |
|
|
|||||||||||||||||||||||||||||
VSC8221 데이터시트(HTML) 39 Page - Microsemi Corporation |
|
39 / 138 page ![]() VSC8221 Data Sheet VMDS-10106 Revision 4.1 December 2006 39 of 40 40 Data is transferred over the iEEE SMi using 32-bit frames with an optional and arbitrary length preamble. The iEEE SMi frame format is described in the following table. • idle: During idle, the MDiO node goes to a high-impedance state. This allows an external pull-up resistor to pull the MDiO node up to a logical “1” state. Since idle mode should not contain any transitions on MDiO, the number of bits is undefined during idle. • Preamble: For the VSC8221, the preamble is optional. By default, preambles are not expected or required. The preamble is a string of “1”s. if it exists, the preamble must be at least one bit, but otherwise may be arbitrarily long. See Mii Register 1.6 for more information. • Start of Frame: A “01” pattern indicates the start of frame. if these bits are anything other than “01”, all following bits are ignored until the next “preamble:0” pattern is detected. • Operation Code: A “10” pattern indicates a read. A “01” pattern indicates a write. if these bits are anything other than “01” or “10”, all following bits are ignored until the next “preamble:0” pattern is detected. • PHY Address: The next five bits are the PHY address. The PHY responds to a message frame only when the received PHY address matches its physical address. The PHY's address is indicated by the CMODE1[2] and CMODE0[3:0] bits. • Register Address: The next five bits are the register address. • Turn-Around: The next two bits are “turn-around” (TA) bits. They are used to avoid contention when a read operation is performed on the MDiO. During read operations, the VSC8221 will drive the second TA bit, which is a logical “0”. • Data: The next sixteen bits are data bits. When data is being read from the PHY, data is valid at the output of the PHY from one rising edge of MDC to the next rising edge of MDC. When data is being written to the PHY, data must be valid around the rising edge of MDC. • idle: The sequence is repeated. The following two figures diagram iEEE SMi read and iEEE SMi write operations. Figure 12. MDiO Read Frame Table 19. SMi Frame Format Direction from VSC8221 Preamble Start of Frame Op Code PHY Address Register Address Turn- Around Data idle # of bits 1+ 2255216 ? Read Output Z’s ZZ ZZ Z’s Z’s Z0 data Z’s input 1’s 01 10 addr addr ZZ Z’s Z’s Write Output Z’s ZZZZZ’s Z’s ZZZ’s Z’s input 1’s 01 01 addr addr 10 data Z’s MDC MDIO Preamble (optional) SFD 1 Z10 Read 1 0 PHY Address A4 A3 A2 A1 A0 R4 R3 R2 R1 R0 Register Address to PHY Z0 TA Register Data from PHY D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 Z Z Idle Idle Z Station Manager Drives MDIO PHY Drives MDIO |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |