15 / 63 page ![]() Figure 5. Voltage conversion routine steps GADG220620221212SA Cells NCELLTCELL_FILTER VB TCELL_FILTER NTC TTEMP_FILTER Die Temp TTEMP_FILTER Table 9. Voltage conversion routine execution parameters Symbol Parameter Test conditions Min. Typ. Max. Unit TMEAS_CYCLE Programmable voltage conversion routine execution period (5 bit) TMEASCYCLE=10ms*CODE - 10 - 310 ms Task execution period TMEAS_CYCLE, must always be greater than the task duration. In case the task execution period is programmed shorter than the task duration, this will result in the task being executed with random periodicity. Figure 6. Correct management of the task execution periodicity GADG220620221219SA TMEAS_CYCLE TADCV_CONV TADCV_CONV TADCV_CONV TADCV_CONV Task execution trigger time 3.4.1 Cell voltage monitor (Cx) During cells voltage monitoring step, the voltage conversion routine measures differential voltages at Cx pins and stores results in VCELL<x> registers. The digital sum of cells is stored in the VCELL_SUM_MEAS register. A cell is converted only if its corresponding VCELL<x>_EN bit is enabled. By default, all cells are disabled. At least 3 cells must be enabled in order to guarantee proper operation. If less than 5 cells are used: • Mount the cells starting from the bottom-most (C0-C1) Measurements are compared to programmable thresholds to detect the failures listed in Table 12. Table 10. Cell voltage monitor diagnostics Fault type Assertion condition IC reaction to assertion Release condition IC reaction to flag clear Maskable Cell UV If a cell voltage falls below VCELL_UV_TH, the corresponding UV counter is incremented by 1 The CELL<x>_UV flag is set If a cell voltage raises above VCELL_UV_TH, the corresponding UV counter is decremented by 1. The discharge FET is restored to the status defined by the DCHG_ON bit VCELL<x>_EN masks measurement execution. The UV flag of a disabled cell can always be cleared L9961 Voltage conversion routine DS14012 - Rev 1 page 15/63 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |