| 전자부품 데이터시트 검색엔진 |
|
AD9549 데이터시트(PDF) 37 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9549 데이터시트(HTML) 37 Page - Analog Devices |
|
37 / 78 page ![]() Preliminary Technical Data AD9549 Rev. PrA | Page 37 of 78 Figure 22: Holdover state diagram Abbreviation Key OvrdRefPin: Override REF SEL pin OvrdHldPin: Override HOLDOVER pin AutoRefSel: Automatic reference select AutoRcov: Automatic holdover recovery AutoHold: Automatic holdover entry || Logical OR & Logical AND % Logical NOT RefA: Reference A selected RefB: Reference B selected HoldOver: Holdover state FailA: Reference A failed FailB: Reference B failed ValidA: Reference A validated ValidB: Reference B validated Figure 23: Holdover State Diagram Abbreviation Key States 1 or 2 are in effect when the device is not in the holdover condition, while states 3 & 4 are in effect when the holdover condition is active. When REF A is selected as the "active" reference, then states 1 or 3 are in effect. When REF B is selected as the "active" reference, then states 2 or 4 are in effect. A transition between states depends on the reference switchover and holdover control register settings, the logic state of the REFSELECT and HOLDOVER pins, and the occurrence of certain events (e.g., a reference failure). The state machine and its relationship to control register and external pin stimuli are shown in the diagram below. The state machine generates a "derived" reference selection and holdover state. The actual control signal sent to the reference switchover logic and the holdover logic, however, depends on the control signals applied to the MUXes. The "dashed" path leading to the REFSELECT and HOLDOVER pins is active when the "auto" mode is selected for reference selection and/or holdover assertion. Reference Recovery Timers Each of the two reference inputs has a dedicated recovery timer. The status of these timers is used by the holdover state machine as part of the decision making process for reverting to a previously faulty reference. For example, suppose that a reference fails (i.e., an LOR or OOL condition is in effect) and |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |