| 전자부품 데이터시트 검색엔진 |
|
ATAM894 데이터시트(PDF) 51 Page - ATMEL Corporation |
|
|
|||||||||||||||||||||||||||||
ATAM894 데이터시트(HTML) 51 Page - ATMEL Corporation |
|
51 / 97 page ![]() 51 4679D–4BMCU–05/05 ATAM894 Timer 3 – Mode 3: Timer/Counter, Internal Trigger Restart and Internal Capture (with TOG2) The counter is driven by an internal or external (T3I) clock source. The output toggle signal of Timer 2 resets the counter. The counter value before the reset is saved in the capture register. If single-action mode is activated for one or both compare registers, the trigger signal restarts the single actions. This mode can be used for frequency measurements or as event counter with time gate (see section “Combination Mode 10”). Figure 6-30. Event Counter with Time Gate Timer 3 - Mode 4: Timer/Counter The timer runs as timer/counter in mode 1, but its output T3O is used as output for the Timer 2 output signal. Timer 3 – Mode 5: Timer/Counter, External Trigger Restart and External Capture (with T3I Input) The Timer 3 runs as timer/counter in mode 2, but its output T3O is used as output for the Timer 2 output signal. 6.3.3.3 Timer 3 Modulator/Demodulator Modes Timer 3 – Mode 6: Carrier Frequency Burst Modulation Controlled by Timer 2 Output Toggle Flip-Flop (M2) The Timer 3 counter is driven by an internal or external clock source. Its compare- and compare mode registers must be programmed to generate the carrier frequency via the output toggle flip-flop. The output toggle flip-flop of Timer 2 is used to enable or disable the Timer 3 output. Timer 2 can be driven by the toggle output signal of Timer 3 or any other clock source (see sec- tion “Combination Mode 11”). Timer 3 – Mode 7: Carrier Frequency Burst Modulation Controlled by SSI Internal Output (SO) The Timer 3 counter is driven by an internal or external clock source. Its compare- and compare mode registers must be programmed to generate the carrier frequency via the output toggle flip-flop. The output (SO) of the SSI is used to enable or disable the Timer 3 output. The SSI should be supplied with the toggle signal of Timer 2 (see section “Combination Mode 12”). 0 01 2 3 45 6 7 8 910 Counter 3 TOG2 T3CP- Register 11 01 2 40 1 T3I 2 3 T3R Capture value = 0 Capture value = 11 Capture value = 4 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |