| 전자부품 데이터시트 검색엔진 |
|
ST72325AR7-Auto 데이터시트(PDF) 171 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
ST72325AR7-Auto 데이터시트(HTML) 171 Page - STMicroelectronics |
|
171 / 243 page ![]() Obsolete Product(s) - Obsolete Product(s) ST72325xxx-Auto I2C bus interface (I2C) Doc ID 13770 Rev 3 171/243 16.7.3 I2C status register 2 (SR2) 1M/SL Master/Slave This bit is set by hardware as soon as the interface is in Master mode (writing START = 1). It is cleared by hardware after detecting a Stop condition on the bus or a loss of arbitration (ARLO = 1). It is also cleared when the interface is disabled (PE = 0). 0: Slave mode 1: Master mode 0SB Start bit (Master mode) This bit is set by hardware as soon as the Start condition is generated (following a write START = 1). An interrupt is generated if ITE = 1. It is cleared by software reading SR1 register followed by writing the address byte in DR register. It is also cleared by hardware when the interface is disabled (PE = 0). 0: No Start condition 1: Start condition generated Table 85. SR1 register description (continued) Bit Name Function SR2 Reset value: 0000 0000 (00h) 76 543 21 0 Reserved AF STOPF ARLO BERR GCAL - RO RORORO RO Table 86. SR2 register description Bit Name Function 7:5 - Reserved. Forced to 0 by hardware. 4AF Acknowledge failure This bit is set by hardware when no acknowledge is returned. An interrupt is generated if ITE = 1. It is cleared by software reading SR2 register or by hardware when the interface is disabled (PE = 0). The SCL line is not held low while AF = 1 but by other flags (SB or BTF) that are set at the same time. 0: No acknowledge failure 1: Acknowledge failure Note: When an AF event occurs, the SCL line is not held low; however, the SDA line can remain low if the last bits transmitted are all 0. It is then necessary to release both lines by software. 3STOPF Stop detection (Slave mode) This bit is set by hardware when a Stop condition is detected on the bus after an acknowledge (if ACK = 1). An interrupt is generated if ITE = 1. It is cleared by software reading SR2 register or by hardware when the interface is disabled (PE = 0). The SCL line is not held low while STOPF = 1. 0: No Stop condition detected 1: Stop condition detected |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |