Back Button ADC3683 Datasheet HTML 16Page - Texas Instruments ADC3683 Datasheet HTML 17Page - Texas Instruments ADC3683 Datasheet HTML 18Page - Texas Instruments ADC3683 Datasheet HTML 19Page - Texas Instruments ADC3683 Datasheet HTML 20Page - Texas Instruments ADC3683 Datasheet HTML 21Page - Texas Instruments ADC3683 Datasheet HTML 22Page - Texas Instruments ADC3683 Datasheet HTML 23Page - Texas Instruments ADC3683 Datasheet HTML 24Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 20 / 70 page
background image
7.3.2 Clock Input
To maximize the ADC SNR performance, the external sampling clock should be low jitter and differential
signaling with a high slew rate. This is especially important in IF sampling applications (Figure 7-10 and Figure
7-11). For less jitter sensitive applications, the device provides the option to operate with single ended signaling
which saves additional power consumption.
Figure 7-10. AC Performance vs Clock Amplitude
(Differential Clock Input)
Figure 7-11. AC Performance vs Clock Amplitude
(Single Ended Clock Input)
7.3.2.1 Single Ended vs Differential Clock Input
The ADC3683-SP can be operated using a differential or a single ended clock input where the single ended
clock consumes less power consumption. However, clock amplitude impacts the ADC aperture jitter and
consequently the SNR. For maximum SNR performance, a large clock signal with fast slew rates needs to
be provided.
• Differential Clock Input: The clock input can be AC coupled externally. The ADC3683-SP provides internal
bias.
• Single Ended Clock Input: This mode needs to be configured using SPI register (0x0E, D2 and D0), or with
the REFBUF pin. In this mode, there is no internal clock biasing, so the clock input needs to be DC coupled
around a 0.9V center. The unused input needs to be AC coupled to ground.
VCM
0.9V
CLKP
CLKM
5kO
5kO
CLKP
CLKM
0.9V
0V
1.8V
+
-
Figure 7-12. External and internal connection using differential (left) and single ended (right) clock input
ADC3683-SP
SBASAB5 – MARCH 2024
www.ti.com
20
Submit Document Feedback
Copyright © 2024 Texas Instruments Incorporated
Product Folder Links: ADC3683-SP



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com