19 / 82 page ![]() DocID16384 Rev 10 19/82 AN3077 Functional safety requirements for application software 81 3.13.1.1 Double Read Digital Inputs 3.13.1.1.1 Hardware elements Double read operation of a digital input is implemented by two general purpose inputs (GPI) of the SIUL unit. SIUL must be configured to allow an input signal to be read from it’s assigned pad. To minimize CCFs, the two input pads must not be physically adjacent (see Section 7, I/O pin/ball configuration for details). 3.13.1.1.2 Safety Integrity Functions Mandatory: Safety integrity is achieved by replicated reading and software comparison by the processing function. The application shall implement the following tests: ● SIUL_SWTEST_REGCRC Note: Rationale: To verify that the configuration of the two pads used corresponds with the expected configuration, and to avoid a CCF caused by incorrectly configured pads ● GPI_SWTEST_CMP Note: Rationale: To verify that the two input values compare Figure 1. Double Read Digital Input 3.13.1.1.3 Software test implementation ● SIUL_SWTEST_REGCRC The SIUL configuration registers are read, then a CRC is calculated. The CRC calculation is compared to the expected CRC value. SIUL I Digital In Double Read Configuration I GPI[y] GPI[x] I = Input Pad |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |