| 전자부품 데이터시트 검색엔진 |
|
AN3077 데이터시트(PDF) 42 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
AN3077 데이터시트(HTML) 42 Page - STMicroelectronics |
|
42 / 82 page ![]() Functional safety requirements for application software AN3077 42/82 DocID16384 Rev 10 ADC_SWTEST_VALCHK The goal of this software test is to verify correct operation of the control and queue logic of the ADC, and also the CTU, if used. This software measures implementation is dependant on the ADC configuration (for example, CTU or CPU mode): When the ADC is used in CPU mode, the acquired value is read by the ADC_CDRn. This register includes ADC_CDRn[VALID] and ADC_CDRn[RESULT] fields as well as channel n converted data (ADC_CDRn[CDATA]). These fields provide status information about the data acquisition. Application software shall read and verify these fields after every acquisition. When the ADC conversion is triggered by the CTU, the acquired digital sample data are stored in a dual queue along with information about the channel that performed the acquisition. Checking the channel information of the acquisition provides sufficient coverage of the control logic and, in part, the queue logic. Note: Implementation hint: If ADC is configured to work in CTU mode, the conversion results are stored in CTU FIFOs (See “Cross-Triggering Unit (CTU)” chapter in Device_Number Reference Manual). Along with the converted data, the converted channel number and ADC module are stored. CTU includes two sets of registers to read this information (FIFO Right aligned data, CTU_FRx, and FIFO Left aligned data, CTU_FLx). User must read these registers to verify if the sequence of the acquired channel is what is expected. ● ADC_SWTEST_OVERSAMPLING In case of Single Read Analog Inputs the ADC_SWTEST_ADCOVERSAMPLING_CMP must be implemented as counter measure against random fault. ADC_SWTEST_OVERSAMPLING is an acquisition redundant in time. It refers to sampling the signal at rate significantly higher than the Nyquist Frequency related to the input signal. In case of fault the acquired values are not correlated with themselves. This SIF compares the acquired value to verify the correlation. Against random fault, three consecutive analog values are converted for each acquisition to implement the ADC_SWTEST_OVERSAMPLING The second acquisition, A2, is faulty because the first converted value is quite different respect the other two (See Figure 13). Figure 13. Series of acquired analog values Faulty Acquisition A1 A2 A3 t |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |