Back Button AN3077 Datasheet HTML 40Page - STMicroelectronics AN3077 Datasheet HTML 41Page - STMicroelectronics AN3077 Datasheet HTML 42Page - STMicroelectronics AN3077 Datasheet HTML 43Page - STMicroelectronics AN3077 Datasheet HTML 44Page - STMicroelectronics AN3077 Datasheet HTML 45Page - STMicroelectronics AN3077 Datasheet HTML 46Page - STMicroelectronics AN3077 Datasheet HTML 47Page - STMicroelectronics AN3077 Datasheet HTML 48Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 44 / 82 page
background image
Functional safety requirements for application software
AN3077
44/82
DocID16384 Rev 10
Mandatory: The shared channels (AN[11:14]) suffer from CCF because they share pads
between each ADC module. Therefore, they are omitted (considered not safe) for double
reads. The comparison of the results is performed by application software (See Figure 14).
Note:
Rationale: ADC_0 and ADC_1 share a pad for the channels (AN[11:14]). Omitting them
from double read eliminates a possible source of CCF.
Mandatory: After boot but before executing the safety function the following tests shall be
executed to detect latent faults (See Section 3.15.1.1.3, Hardware BIST and
Section 3.15.1.1.3.1, Hardware BIST implementation):
●
SUPPLY SELF-TEST
●
RESISTIVE-CAPACITIVE SELF-TEST
●
CAPACITIVE SELF-TEST
Note:
Rationale: To check the integrity of the ADC modules
Mandatory: Before running the HW self-test, the customer must copy the threshold values
of the analog watchdogs from test sector into the watchdog registers (See “Self test analog
watchdog” section of the “Analog-to-Digital Converter (ADC)” chapter in Device_Number
Reference Manual).
Note:
Rationale: To set the correct threshold for the self-test
3.15.1.2.2
Safety Integrity Functions
Safety integrity is achieved by replicated acquisition with separate analog input channels
and software comparison by the processing function (See Figure 14).
Mandatory: The following software test must be implemented by the application software:
ADC0_SWTEST_REGCRC, ADC1_SWTEST_REGCRC, SIUL_SWTEST_REGCRC
Note:
Rationale: To verify that the configuration of the module used by this safety function
corresponds with what is expected
Note:
Rationale: To avoid CCF caused by improper configuration of the pads
Mandatory: In addition, the software test ADC_SWTEST_CMP must be implemented to
compare the channel reads.
Note:
Rationale: To verify that the two sets of read data compare
It is important to note that this safety integrity function might be applied in addition to Single
Analog Read Inputs, which increases diagnostic coverage.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com