72 / 174 page ![]() 72 www.national.com Revision 1.1 4.0 LPC Bus Interface With the exception of the Glue Functions, the host can access all the functional blocks of the PC87373 device through the LPC bus. 4.1 OVERVIEW The LPC host interface supports 8-bit I/O Read, 8-bit I/O Write and 8-bit DMA transactions, as defined in Intel’s LPC Interface Specification, Revision 1.0. 4.2 LPC TRANSACTIONS The LPC interface of the PC87373 device responds to the following LPC transactions: • 8-bit I/O read and write cycles • 8-bit DMA read and write cycles • DMA request cycles 4.3 LPCPD FUNCTIONALITY The PC87373 device supports LPCPD functionality. LPCPD is used when the VDD3 power supply is not shared by all the devices connected to the LPC bus. The LPCPD signal conforms with Intel’s LPC Interface Specification, Revision 1.00. Note that if the PC87373 power supply is on while LPCPD is active (indicating the LPC bus is powered down), the PC87373 does not have to be reset when LPCPD is de-asserted (indicating that power is returned to the LPC bus). When the LPCPD functionality is not required, the LPCPD pin must be left unconnected. Connecting the LPCPD pin to the VDD3 power supply is not recommended. 4.4 INTERRUPT SERIALIZER The Interrupt Serializer translates parallel interrupt request (PIRQ) signals received from internal IRQ sources into serial in- terrupt request data transmitted over the SERIRQ bus. This enables devices that support only parallel IRQs to be integrated into a system that supports only serial IRQs like the LPC bus. Each internal IRQ is fed into a Mapping, Enable and Polarity Control block, which maps the IRQ to its associated IRQ num- bers (see Table 12 on page 37). The resulting IRQs are then fed into the Interrupt Serializer, where they are translated into serial data and then transmitted over the SERIRQ bus. Each interrupt number is assigned a time slot in the SERIRQ frame. Different IRQ sources in the PC87373 device cannot share the same interrupt number and thus cannot share the same time slot in the SERIRQ frame. When a transition is detected on an IRQ source, the new value of the IRQ source is transmitted over the SERIRQ bus during the corresponding IRQ slot. For example, when a transition on the Serial Port IRQ is detected, the new value of the Serial Port IRQ is transmitted during time slot n of the SERIRQ bus. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |