| 전자부품 데이터시트 검색엔진 |
|
FXLS93421 데이터시트(PDF) 46 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
FXLS93421 데이터시트(HTML) 46 Page - NXP Semiconductors |
|
46 / 254 page ![]() NXP Semiconductors FXLS9xxxx Dual channel inertial sensor DEVINIT Condition 0 Normal operation 1 Device Initialization in Process Table 54. Device initialization (DEVINIT) 11.2.2.9 VBUF under-voltage error (VBUFUV_ERR) The VBUF under-voltage error bit is set if the VBUF voltage falls below the voltage specified in Section 10.4. See Section 11.4 for details on the VBUF under-voltage monitor. A common timer is used for all error bits in the DEVSTAT1 register. If any supply error is present, the timer is reset to tUVOV_RCV. This bit is cleared based on the state of the SUP_ERR_DIS bit in the DEVLOCK_WR register as shown in Section 11.2.2.5. VBUFUV_ERR Error condition 0 No error detected 1 VBUF Voltage Low Table 55. VBUF under-voltage error (VBUFUV_ERR) 11.2.2.10 BUS IN under-voltage error (BUSINUV_ERR) The BUS IN under-voltage error bit is set if the BUS_IN voltage falls below the voltage specified in Section 10.4. See Section 11.4 for details on the BUS IN under-voltage monitor. A common timer is used for all error bits in the DEVSTAT1 register. If any supply error is present, the timer is reset to tUVOV_RCV. This bit is cleared based on the state of the SUP_ER-R_DIS bit in the DEVLOCK_WR register as shown in Section 11.2.2.5. BUSINUV_ERR Error condition 0 No error detected 1 BUS_IN Voltage Low Table 56. BUS IN under-voltage error (BUSINUV_ERR) 11.2.2.11 VBUF over-voltage error (VBUFOV_ERR) The VBUF over-voltage error bit is set if the VBUF voltage rises above the voltage specified in Section 10.4. See Section 11.4 for details on the VBUF over-voltage monitor. A common timer is used for all error bits in the DEVSTAT1 register. If any supply error is present, the timer is reset to tUVOV_RCV. This bit is cleared based on the state of the SUP_ERR_DIS bit in the DEVLOCK_WR register as shown in Section 11.2.2.5. VBUFUV_ERR Error condition 0 No error detected 1 VBUF Voltage High Table 57. VBUF over-voltage error (VBUFOV_ERR) 11.2.2.12 Internal analog regulator voltage out of range error (INTREGA_ERR) The internal analog regulator voltage out of range error bit is set if the internal analog regulator voltage falls outside expected limits. A common timer is used for all error bits in the DEVSTAT1 register. If any supply error is present, the timer is reset to tUVOV_RCV. This bit is cleared based on the state of the SUP_ERR_DIS bit in the DEVLOCK_WR register as shown in Section 11.2.2.5. FXLS9xxxx All information provided in this document is subject to legal disclaimers. © NXP B.V. 2021. All rights reserved. Product data sheet Rev. 6 — 8 February 2021 46 / 254 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |