| 전자부품 데이터시트 검색엔진 |
|
CC1110-RTR1 데이터시트(PDF) 171 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
CC1110-RTR1 데이터시트(HTML) 171 Page - Texas Instruments |
|
171 / 203 page ![]() CC1110 CC1110 PRELIMINARY Datasheet (Rev. 1.01) SWRS033A Page 171 of 202 voltage or temperature has changed significantly). 15.15 Output Power Programming The RF output power level from the device has two levels of programmability, as illustrated in Figure 39. Firstly, the PA_TABLE7- PA_TABLE0 registers can hold up to eight user selected output power settings. Secondly, the 3-bit FREND0.PA_POWER value selects which PA_TABLE7-0 register to use. This two-level functionality provides flexible PA power ramp up and ramp down at the start and end of transmission, as well as ASK modulation shaping.n each case, all the PA power settings from PA_TABLE0 from i up to the FREND0.PA_POWER value are used. The power ramping at the start and at the end of a packet can be turned off by setting FREND0.PA_POWER to zero and then programming the desired output power in PA_TABLE0. Table 49 contains recommended PA_TABLE settings for various output levels and frequency bands, together with current consumption in the RF transceiver. With ASK modulation, the eight power settings are used for shaping. The modulator contains a counter that counts up when transmitting a one and down when transmitting a zero. The counter counts at a rate equal to 8 times the symbol rate. The counter saturates at FREND0.PA_POWER and 0 respectively. This counter value is used as an index for a lookup in the power table. Thus, in order to utilize the whole table, FREND0.PA_POWER should be 7 when ASK is active. The shaping of the ASK signal is dependent on the configuration in the PA_TABLE7-0 registers. e.g 6 PA_POWER[2:0] in FREND0 register PA_TABLE0[7:0] PA_TABLE1[7:0] PA_TABLE2[7:0] PA_TABLE3[7:0] PA_TABLE4[7:0] PA_TABLE5[7:0] PA_TABLE6[7:0] PA_TABLE7[7:0] Index into PA_TABLE7-0 The PA uses this setting. Settings 0 to PA_POWER are used during ramp-up at start of transmission and ramp-down at end of transmission, and for ASK/OOK modulation. The SmartRF® Studio software should be used to get optimum PATABLE settings for various output powers. Figure 39: PA_POWER and PA_TABLE7-0 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |