| 전자부품 데이터시트 검색엔진 |
|
PIFE32251B-R47MS 데이터시트(PDF) 32 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
PIFE32251B-R47MS 데이터시트(HTML) 32 Page - Texas Instruments |
|
32 / 96 page ![]() 32 TPS65094 SWCS133C – SEPTEMBER 2015 – REVISED FEBRUARY 2019 www.ti.com Submit Documentation Feedback Product Folder Links: TPS65094 Detailed Description Copyright © 2015–2019, Texas Instruments Incorporated (1) All Power Good signals must immediately deassert at the loss of any of the qualifying signals, or at the occurrence of a fault condition. 6.3 Feature Description 6.3.1 Power Good (PGOOD) The TPS65094x device provides information on status of VRs through two Power Good signals or pins. Table 6-2 defines which signals are required to assert the PGOOD signals. Table 6-2. Power Good Summary POWER GOOD(1) QUALIFYING SIGNALS (LOGICAL AND) RSMRSTB ✓ ✓ ✓ ✓ ✓ ✓ PCH_PWROK ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 6.3.2 Register Reset Conditions All registers are reset if any of the following conditions are met: • VSYS pin voltage drops below 5.4 V • Falling edge of PMICEN for OTPs where LDOA1 is not "Always On" • Falling edge of THERMTRIPB while RSMRSTB = 1 • Power fault of any regulator where xx_FLTMSK = 0 (see Section 6.6.27, PWR_FAULT_MASK1 Register, and Section 6.6.28, PWR_FAULT_MASK2 Register) • PMIC critical temperature shutdown • Software shutdown (writing 1 to the SDWN bit in the FORCESHUTDN register, see Figure 6-35) Additionally, BUCK1 and BUCK2 VID registers are reset on the falling edge of SLP_S0IXB and SLP_S3B. 6.3.3 SMPS Voltage Regulators The buck controllers integrate gate drivers for external power stages with programmable current limit (set by an external resistor at ILIMx pin), which allows for optimal selection of external passive components based on the desired system load. The buck converters include integrated power stage and require a minimum number of pins for power input, inductor, and output voltage feedback input. Combined with high-frequency switching, all these features allow use of inductors in small form factor, thus reducing the total cost and size of the system. BUCK3–BUCK6 have selectable auto- and forced-PWM mode through the BUCKx_MODE bit in the BUCKxCTRL register. In default auto mode, the VR automatically switches between PWM and PFM depending on the output load to maximize efficiency. The host cannot select Forced PWM mode for other SMPS VRs as they stay in auto mode at all times. See Table 6-3 and Table 6-4 for the full voltage tables for all SMPS regulators. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |