26 / 63 page ![]() 2–14 2.1.6.1 Auto-flow Control (See Figure 2–4) Auto-flow control is composed of auto-CTS and auto-RTS. With auto-CTS, CTS must be low before the transmit FIFO register can emit data (see Figure 2–4). With auto-RTS, RTS becomes high when the receiver is empty or the threshold has not been reached. When RTS is connected to the CTS, data transmission does not occur unless the receiver FIFO register has empty space. Overrun errors are eliminated when UART1 and UART2 are TIR2000 or other autoflow control devices with enabled flow control. When UART1 and UART2 are not autoflow control devices with enabled flow control an overrun error occurs if the transmit data exceeds the data receive FIFO-read capacity. RCV FIFO Serial to Parallel Flow Control XMT FIFO Parallel to Serial Flow Control SIN RTS SOU T CTS D7 – D0 XMT FIFO Serial to Parallel Flow Control RCV FIFO Parallel to Serial Flow Control SOUT CTS SIN RTS D7 – D0 UART1 UART2 Figure 2–4. Example of Auto-flow Contol (Auto-RTS and Auto-CTS) 2.1.6.2 Auto-RTS (See Figure 2–4) Auto-RTS data-flow control originates in the receiver timing and control block and is linked to the programmed RCV-FIFO trigger level. When the receiver FIFO trigger level reaches a trigger level of 1, 4, 8, or 14 in the 16-byte mode or 1, 16, 32, or 56 in the 64-byte mode, RTS is de-asserted. The sending UART may send an additional byte after the trigger level is reached (assuming the sending device has another byte to send) because it may not recognize the de-assertion of RTS until after it begins to send the additional byte. RTS is automatically reasserted when the RX FIFO register is emptied by reading the receiver-buffer register (RBR). The reassertion signals the sending UART to continue transmitting data. 2.1.6.3 Auto-CTS (See Figure 2–4) The transmitter circuitry checks CTS before sending the next data byte. If CTS is low, the transmitter sends the next byte. To stop the transmitter from sending the following byte, CTS must be released before the middle of the last stop bit that is currently being sent. The auto-CTS function reduces interrupts to the host system. When the flow control is enabled, the CTS level changes and does not trigger host interrupts because the device automatically controls its own transmitter. Without auto-CTS, the transmitter sends any data present in the transmit FIFO register and a receiver overrun error can result. To enable the auto-RTS and auto-CTS modes of operation bit 5 of the modem-control register must be set to a 1. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |