| 전자부품 데이터시트 검색엔진 |
|
TIR2000 데이터시트(PDF) 34 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TIR2000 데이터시트(HTML) 34 Page - Texas Instruments |
|
34 / 63 page ![]() 3–4 2 0 Number of stop bits. Bit 2 specifies either 1, 1.5, or 2 stop bits in each transmitted character. The number of stop bits generated is defined as in the following table. The receiver clocks only the first stop bit, regardless of the number of stop bits selected. Bit 2 bit specified word lengths and number of stop bits generated are as follows: BIT 2 WORD LENGTH SPECIFIED BY BITS 0 & 1 NUMBER OF STOP BIT GENERATED 0 Any word length 1 1 5 bits 1.5 1 6 bits 2 1 7 bits 2 1 8 bits 2 3 0 Parity enable bit. When bit 3 is a 1, a parity bit is generated in data transmitted between the last data word bit and the first stop bit. In the receiver, the parity bit is checked when bit 3 is set. When bit 3 is a 0, no parity is generated or checked. 4 0 Even parity select bit. When bit 3 is set, a logic 1 in bit 4 produces even parity and a logic 0 in bit 4 produces odd parity. 5 0 Stick-parity bit. When bits 3, 4 and 5 are a 1, the parity bit is transmitted and checked as a logic 0. When bits 3 and 5 are a 1 and bit 4 is a 0, the parity bit is transmitted and checked as a logic 1. When bit 5 is a 0, stick parity is disabled. 6 0 Break control bit. Bit 6 is set to a 1 to force a break condition; i.e., a condition where the serial output (SOUT) is forced to spacing (0) state. When bit 6 is set to 0, the break condition is disabled. Bit 6 only affects the SOUT. 7 0 Divisor-latch-access bit (DLAB). Bit 7 must be set to a 1 to access the divisor latches of the baud rate generator or bit 5 of the FIFO control register (FCR). Bit 7 must be set to 0 to access the receiver buffer register, the transmitter holding register, or the interrupt enable register. 3.7 Modem Control Register (MCR) - (read and write) Address: 4 (Hex) Bit Definitions: BIT NO. DESCRIPTION 0 Data terminal ready (DTR). Bit 0 controls DTR. 1 Request to send (RTS). Bit 1 controls RTS. 2 Reserved 3 Enable IRQ. When set to a 1, the selected IRQ channel is enabled. 4 Loop back mode enable. When set to 1, bit 4 enables the loop back mode, i.e., it provides a local loop-back feature for diagnostic testing of the UART. 5 Flow-control enable (AFE). 6 Reserved 7 Reserved |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |