| 전자부품 데이터시트 검색엔진 |
|
DSP56362AD 데이터시트(PDF) 12 Page - Motorola, Inc |
|
|
|||||||||||||||||||||||||||||
DSP56362AD 데이터시트(HTML) 12 Page - Motorola, Inc |
|
12 / 168 page ![]() 1-4 DSP56362 Advance Information MOTOROLA Signal/Connection Descriptions Ground GROUND Table 1-3 Grounds Ground Name Description GNDP PLL Ground—GNDP is a ground dedicated for PLL use. The connection should be provided with an extremely low-impedance path to ground. VCCP should be bypassed to GNDP by a 0.47 µF capacitor located as close as possible to the chip package. There is one GNDP connection. GNDP1 PLL Ground 1—GNDP1 is a ground dedicated for PLL use. The connection should be provided with an extremely low-impedance path to ground. There is one GNDP1 connection. GNDQ (4) Quiet Ground—GNDQ is an isolated ground for the internal processing logic. This connection must be tied externally to all other chip ground connections. The user must provide adequate external decoupling capacitors. There are four GNDQ connections. GNDA (4) Address Bus Ground—GNDA is an isolated ground for sections of the address bus I/O drivers. This connection must be tied externally to all other chip ground connections. The user must provide adequate external decoupling capacitors. There are four GNDA connections. GNDD (4) Data Bus Ground—GNDD is an isolated ground for sections of the data bus I/O drivers. This connection must be tied externally to all other chip ground connections. The user must provide adequate external decoupling capacitors. There are four GNDD connections. GNDC (2) Bus Control Ground—GNDC is an isolated ground for the bus control I/O drivers. This connection must be tied externally to all other chip ground connections. The user must provide adequate external decoupling capacitors. There are two GNDC connections. GNDH Host Ground—GNDH is an isolated ground for the HDI08 I/O drivers. This connection must be tied externally to all other chip ground connections. The user must provide adequate external decoupling capacitors. There is one GNDH connection. GNDS (2) SHI, ESAI, DAX, and Timer Ground—GNDS is an isolated ground for the SHI, ESAI, DAX, and Timer I/O drivers. This connection must be tied externally to all other chip ground connections. The user must provide adequate external decoupling capacitors. There are two GNDS connections. Freescale Semiconductor, Inc. For More Information On This Product, Go to: www.freescale.com |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |