25 / 82 page ![]() MPC8323E PowerQUICC II Pro Integrated Communications Processor Family Hardware Specifications, Rev. 4 Freescale Semiconductor 25 Ethernet and MII Management 8.3.1 MII Management DC Electrical Characteristics MDC and MDIO are defined to operate at a supply voltage of 3.3 V. The DC electrical characteristics for MDIO and MDC are provided in Table 27. 8.3.2 MII Management AC Electrical Specifications Table 28 provides the MII management AC timing specifications. Table 27. MII Management DC Electrical Characteristics When Powered at 3.3 V Parameter Symbol Conditions Min Max Unit Supply voltage (3.3 V) OVDD — 2.97 3.63 V Output high voltage VOH IOH = –1.0 mA OVDD = Min 2.10 OVDD + 0.3 V Output low voltage VOL IOL = 1.0 mA OVDD = Min GND 0.50 V Input high voltage VIH —2.00 — V Input low voltage VIL —— 0.80 V Input current IIN 0 V ≤ VIN ≤ OVDD —±5 μA Table 28. MII Management AC Timing Specifications At recommended operating conditions with OVDD is 3.3 V ± 10%. Parameter/Condition Symbol1 Min Typical Max Unit Notes MDC frequency fMDC —2.5 — MHz — MDC period tMDC —400 — ns — MDC clock pulse width high tMDCH 32 — — ns — MDC to MDIO delay tMDKHDX 10 — 70 ns — MDIO to MDC setup time tMDDVKH 5— — ns — MDIO to MDC hold time tMDDXKH 0— — ns — MDC rise time tMDCR — — 10 ns — MDC fall time tMDHF — — 10 ns — Note: 1. The symbols used for timing specifications follow the pattern of t(first two letters of functional block)(signal)(state)(reference)(state) for inputs and t(first two letters of functional block)(reference)(state)(signal)(state) for outputs. For example, tMDKHDX symbolizes management data timing (MD) for the time tMDC from clock reference (K) high (H) until data outputs (D) are invalid (X) or data hold time. Also, tMDDVKH symbolizes management data timing (MD) with respect to the time data input signals (D) reach the valid state (V) relative to the tMDC clock reference (K) going to the high (H) state or setup time. For rise and fall times, the latter convention is used with the appropriate letter: R (rise) or F (fall). |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |