| 전자부품 데이터시트 검색엔진 |
|
ADPD4100 데이터시트(PDF) 45 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADPD4100 데이터시트(HTML) 45 Page - Analog Devices |
|
45 / 101 page ![]() Data Sheet ADPD4100/ADPD4101 Rev. 0 | Page 45 of 101 Table 27. Relevant Configuration Registers for ECG Measurement Using Sleep Float Mode Group Time Slot A Register Address1 Bit Field Name Description Signal Path Setup 0x0100, Bits[13:12] SAMPLE_TYPE_x Leave at the default setting (0) for default sampling mode. 0x0100, Bits[11:10] INPUT_R_SELECT_x Set to 0x0 for 500 Ω series input resistor. 0x0101, Bits[8:0] AFE_PATH_CFG_x Set to 0x0E6 for TIA, integrator, and ADC. Bypass the BPF. 0x0101, Bits[15:12] PRE_WIDTH_x Set to 0 to skip preconditioning period. 0x0102, Bits[15:0] INPxx_x Set to 0x7 to enable desired inputs connected to Channel 1 as defined in PAIRxx. 0x0103, Bits[4:12] PRECON_x Set to 0x0 to float the inputs during preconditioning. 0x0020, Bits[15:0] INP_SLEEP_xx Set to 0x0 to float inputs during sleep. 0x0021, Bits[3:0] PAIRxx Set to 1 to configure selected inputs as a differential pair. 0x0104, Bits[5:0] TIA_GAIN_CHx_x Select TIA gain. 0x0104, Bits[9:8] AFE_TRIM_VREF_x Set to 0x2 to set TIA_VREF = 0.9 V. Float Mode Configuration 0x0107, Bits[15:8] NUM_INT_x Set to 1 for a single integration per group of ADC conversions. 0x0107, Bits[7:0] NUM_REPEAT_x Number of sequence repeats. 0x0108, Bits[13:12] MOD_TYPE_x Set to 0x1 for float type operation. 0x0108, Bits[9:0] MIN_PERIOD_x Set to 0. Minimum period is not applicable to sleep float mode with a single integration. 0x010A, Bits[4:0] INTEG_WIDTH_x Integration time in µs. Set to MOD_WIDTH_x + 1. 0x010A, Bits[10:8], Bits[14:12] CHx_AMP_DISABLE_x Set 0x010A, Bit 9 to 1 to power down BPF for Channel 1, Bit 13 to 1 to power down BPF for Channel 2 if Channel 2 is enabled. 0x010B, Bits[12:0] INTEG_OFFSET_x Integration sequence start time. Set to (MOD_OFFSET_x − INTEG_WIDTH_x – 250 ns). 0x010C, Bits[15:8] MOD_WIDTH_x Sets width of connect pulse in 1 μs increments. MOD_WIDTH_x × NUM_REPEAT_x determines the time to transfer the charge from the external capacitor. Set MOD_WIDTH_x × NUM_REPEAT_x to approximately three time constants based on the time constant created between the external capacitor and the series input resistor (500 Ω or 6500 Ω based on setting of INPUT_R_SELECT_x). 0x010C, Bits[7:0] MOD_OFFSET_x Sets start time of first connect pulse in 1 μs increments. Set to INTEG_WIDTH_x + 3. 1 This is the Time Slot A register address. Add 0x020 for the identical register address for each subsequent time slot. For example, Register 0x0100 is the location for SAMPLE_TYPE_A. For Time Slot B, this register is at Address 0x0120. For Time Slot C, this register is at Address 0x0140. For Time Slot D, this register is at Address 0x0160, and so on. Sleep Float Mode with Multiple Charge Transfers In ECG measurement, there can be a dc offset voltage on the order of tens or hundreds of millivolts or even greater when the electrode skin contact impedance is high and/or the electrodes are made of different materials with large half cell potential mismatch. The dc offset voltage uses a significant amount of the dynamic range available for the ECG measurement. The maximum amount of charge that the ADPD4100/ADPD4101 can accommodate for a single sample is ~7.5 pC with the 200 kΩ TIA gain setting. The maximum allowable charge per sample scales inversely with the gain of the TIA. The presence of a large dc offset voltage creates excess charge on the sensing capacitor, which can saturate the input to the ADC. For example, 100 mV of dc offset voltage adds an additional 47 pC of charge to the 470 pF capacitor. To accommodate the dc offset voltage without reducing the size of the sensing capacitor, the recommendation is to reduce the TIA gain to 50 kΩ or 100 kΩ, and to transfer the accumulated charge in multiple short pulses. For example, to transfer 47 pC of charge from the sensing capacitor to the integrator, the TIA gain of 50 kΩ can accommodate 30 pC of charge per sample. Setting RIN = 6.5 kΩ limits the rate of charge transfer into the TIA with an RC time constant of 2 × 6.5 kΩ × 470 pF = 6.1 μs. Using multiple short modulation pulses, which can be as short as 1 µs, allows a smaller percentage of the overall charge to be transferred and integrated per pulse to avoid saturating the TIA. Multiple transfer cycles are then used to fully discharge the sensing capacitor. The ADPD4100/ADPD4101 automatically sum the results of the transfer cycles and report the total charge. The timing for this mode is the same as shown in Figure 53 except the device is set up for multiple modulation pulses. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |