| 전자부품 데이터시트 검색엔진 |
|
DSP56364 데이터시트(PDF) 25 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
DSP56364 데이터시트(HTML) 25 Page - Freescale Semiconductor, Inc |
|
25 / 148 page ![]() Reset, Stop, Mode Select, and Interrupt Timing DSP56364 Technical Data, Rev. 4.1 Freescale Semiconductor 3-9 29 Delay from IRQA, IRQB, IRQD, NMI assertion to external memory (DMA source) access address out valid 4.25 × T C + 2.0 44.0 — ns 1 V CC = 3.3 V ± 0.16 V; TJ = 0°C to + 105°C, CL = 50 pF 2 Use expression to compute maximum value. 3 Periodically sampled and not 100% tested 4 For an external clock generator, RESET duration is measured during the time in which RESET is asserted, V CC is valid, and the EXTAL input is active and valid. For internal oscillator, RESET duration is measured during the time in which RESET is asserted and VCC is valid. The specified timing reflects the crystal oscillator stabilization time after power-up. This number is affected both by the specifications of the crystal and other components connected to the oscillator and reflects worst case conditions. When the VCC is valid, but the other “required RESET duration” conditions (as specified above) have not been yet met, the device circuitry will be in an uninitialized state that can result in significant power consumption and heat-up. Designs should minimize this state to the shortest possible duration. 5 For an external clock generator, RESET duration is measured during the time in which RESET is asserted, V CC is valid, and the EXTAL input is active and valid. For internal oscillator, RESET duration is measured during the time in which RESET is asserted and VCC is valid. The specified timing reflects the crystal oscillator stabilization time after power-up. This number is affected both by the specifications of the crystal and other components connected to the oscillator and reflects worst case conditions. When the VCC is valid, but the other “required RESET duration” conditions (as specified above) have not been yet met, the device circuitry will be in an uninitialized state that can result in significant power consumption and heat-up. Designs should minimize this state to the shortest possible duration. 6 When using fast interrupts and IRQA, IRQB, and IRQD are defined as level-sensitive, timings 19 through 21 apply to prevent multiple interrupt service. To avoid these timing restrictions, the deasserted Edge-triggered mode is recommended when using fast interrupts. Long interrupts are recommended when using Level-sensitive mode. 7 WS = number of wait states (measured in clock cycles, number of T C) 8 This timing depends on several settings: For PLL disable, using internal oscillator (PLL Control Register (PCTL) Bit 16 = 0) and oscillator disabled during Stop (PCTL Bit 17 = 0), a stabilization delay is required to assure the oscillator is stable before executing programs. In that case, resetting the Stop delay (OMR Bit 6 = 0) will provide the proper delay. While it is possible to set OMR Bit 6 = 1, it is not recommended and these specifications do not guarantee timings for that case. For PLL disable, using internal oscillator (PCTL Bit 16 = 0) and oscillator enabled during Stop (PCTL Bit 17=1), no stabilization delay is required and recovery time will be minimal (OMR Bit 6 setting is ignored). For PLL disable, using external clock (PCTL Bit 16 = 1), no stabilization delay is required and recovery time will be defined by the PCTL Bit 17 and OMR Bit 6 settings. For PLL enable, if PCTL Bit 17 is 0, the PLL is shutdown during Stop. Recovering from Stop requires the PLL to get locked. The PLL lock procedure duration, PLL Lock Cycles (PLC), may be in the range of 0 to 1000 cycles. This procedure occurs in parallel with the stop delay counter, and stop recovery will end when the last of these two events occurs. The stop delay counter completes count or PLL lock procedure completion. PLC value for PLL disable is 0. The maximum value for ETC is 4096 (maximum MF) divided by the desired internal frequency (i.e., for 100 MHz it is 4096/100 MHz = 40 μs). During the stabilization period, T C, TH, and TL will not be constant, and their width may vary, so timing may vary as well. 9. If PLL does not lose lock. Table 3-7 Reset, Stop, Mode Select, and Interrupt Timing1 (continued) No. Characteristics Expression2 Min Max Unit |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |