| 전자부품 데이터시트 검색엔진 |
|
DSP56364 데이터시트(PDF) 20 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
DSP56364 데이터시트(HTML) 20 Page - Freescale Semiconductor, Inc |
|
20 / 148 page ![]() AC Electrical Characteristics DSP56364 Technical Data, Rev. 4.1 3-4 Freescale Semiconductor 3.5 AC Electrical Characteristics The timing waveforms shown in the AC electrical characteristics section are tested with a VIL maximum of 0.3 V and a VIH minimum of 2.4 V for all pins except EXTAL, which is tested using the input levels shown in Note 8 of the previous table. AC timing specifications, which are referenced to a device input signal, are measured in production with respect to the 50% point of the respective input signal’s transition. DSP56364 output levels are measured with the production test machine VOL and VOH reference levels set at 0.4 V and 2.4 V, respectively. NOTE Although the minimum value for the frequency of EXTAL is 0 MHz, the device AC test conditions are 15 MHz and rated speed. 3.6 Internal Clocks 5 This characteristic does not apply to PCAP. 6 Section 5, "Design Considerations" provides a formula to compute the estimated current requirements in Normal mode. In order to obtain these results, all inputs must be terminated (i.e., not allowed to float). Measurements are based on synthetic intensive DSP benchmarks. The power consumption numbers in this specification are 90% of the measured results of this benchmark. This reflects typical DSP applications. Typical internal supply current is measured with VCC = 3.3 V at TJ = 105°C. Maximum internal supply current is measured with VCC = 3.46 V at TJ = 105°C. 7 In order to obtain these results, all inputs must be terminated (i.e., not allowed to float). PLL signal is disabled during Stop state. 8 In order to obtain these results, all inputs, which are not disconnected at Stop mode, must be terminated (i.e., not allowed to float). Table 3-4 Internal Clocks Characteristics Symbol Expression1, 2 Min Typ Max Internal operation frequency with PLL enabled f — (Ef × MF)/ (PDF × DF) — Internal operation frequency with PLL disabled f — Ef/2 — Internal clock high period TH • With PLL disabled — ETC — • With PLL enabled and MF ≤ 40.49 × ET C × PDF × DF/MF —0.51 × ET C × PDF × DF/MF • With PLL enabled and MF > 4 0.47 × ET C × PDF × DF/MF —0.53 × ET C × PDF × DF/MF |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |